Nitric oxide PLIF measurements in the hypersonic materials environmental test system (HYMETS)

J Inman, B Bathel, C Johansen, P Danehy… - 49th AIAA Aerospace …, 2011 - arc.aiaa.org
… from the ablation of test samples, and 4) measurements of rotational, vibrational, and … PLIF
in HYMETS and progress to varying degrees towards all four of these goals. Using NO PLIF, …

Nitric-oxide planar laser-induced fluorescence measurements in the hypersonic materials environmental test system

JA Inman, BF Bathel, CT Johansen, PM Danehy… - AIAA journal, 2013 - arc.aiaa.org
… (PLIF) flow visualization in an arcjet as well as the first nonintrusive measurements of radial
and axial velocity in HYMETS … Using NO PLIF, we have demonstrated that flow visualization …

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

PM Danehy - uknowledge.uky.edu
measurement system has been applied for the first time in the HYMETS (Hypersonic Materials
Environmental Test System) … fluorescence of naturally occurring nitric oxide (NO) has been …

Simultaneous laser-induced fluorescence of nitric oxide and atomic oxygen in the hypersonic materials environment test system arcjet facility

C Johansen, D Lincoln, B Bathel, J Inman… - (Lisbon 2014) The …, 2014 - ntrs.nasa.gov
… For example, Doppler-shift planar laser-induced fluorescence (PLIF) velocimetry can require
… O-atom LIF measurements are obtained in the freestream of the HYMETS facility for a wide …

Nitric Oxide Laser-Induced Fluorescence Rotational Thermometry in a Hypersonic Non-Equilibrium Flow

CC McDougall, CT Johansen… - AIAA Scitech 2020 …, 2020 - arc.aiaa.org
nitric oxide (NO) planar laser-induced fluorescence (PLIF) … in the Hypersonic Materials
Environmental Test System (HyMETS) … -based measurements that can be performed in HyMETS

Simultaneous nitric oxide/atomic oxygen laser-induced fluorescence in an arcjet facility

CT Johansen, DA Lincoln, BF Bathel… - … of Thermophysics and …, 2016 - arc.aiaa.org
… for the Hypersonic Materials Environmental Test System facility. … flow-visualization
measurements of NO PLIF in the freestream … are obtained in the freestream of the HYMETS facility …

[PDF][PDF] Quantitative hypersonic flow measurements using planar laser-induced fluorescence

CC McDougall - 2018 - prism.ucalgary.ca
… in the NASA Langley Hypersonic Materials Environment Test System (HyMETS). … test
methods to quantitatively analyze raw Nitric Oxide (NO) Planar-Laser Induced Fluorescence (PLIF) …

Computational predictions of the hypersonic material environmental test system arcjet facility

AJ Brune, WE Bruce III, DE Glass… - Journal of thermophysics …, 2019 - arc.aiaa.org
… This paper is organized to first present an overview of the HYMETS facility configuration and
PLIF of naturally occurring NO to obtain radial and axial velocity measurements at a test

Aerothermodynamic Measurements of Hypersonic Non-Equilibrium Flows

CC McDougall - 2022 - ntrs.nasa.gov
… of nitric oxide (NO) PLIF experiments was designed and performed in the Hypersonic Materials
Environmental Test System (HyMETS) … A detailed explanation of the HyMETS NO-PLIF

Review of planar laser-induced fluorescence measurements in the NASA Langley 31-Inch Mach 10 Air Tunnel

PM Danehy, BF Bathel, NS Rodrigues… - AIAA SCITECH 2024 …, 2024 - arc.aiaa.org
… the use of nitric oxide PLIF for flow visualization, velocity and temperature measurement
in … , including the HYMETS materials test facility, the Hypersonics combustion laboratory in …