Noise mapping and removal in complex-valued multi-channel MRI via optimal shrinkage of singular values

KM Huynh, WT Chang, SH Chung, Y Chen… - … Conference on Medical …, 2021 - Springer
KM Huynh, WT Chang, SH Chung, Y Chen, Y Lee, PT Yap
International Conference on Medical Image Computing and Computer-Assisted …, 2021Springer
In magnetic resonance imaging (MRI), noise is a limiting factor for higher spatial resolution
and a major cause of prolonged scan time, owing to the need for repeated scans. Improving
the signal-to-noise ratio is therefore key to faster and higher-resolution MRI. Here we
propose a method for mapping and reducing noise in MRI by leveraging the inherent
redundancy in complex-valued multi-channel MRI data. Our method leverages a provably
optimal strategy for shrinking the singular values of a data matrix, allowing it to outperform …
Abstract
In magnetic resonance imaging (MRI), noise is a limiting factor for higher spatial resolution and a major cause of prolonged scan time, owing to the need for repeated scans. Improving the signal-to-noise ratio is therefore key to faster and higher-resolution MRI. Here we propose a method for mapping and reducing noise in MRI by leveraging the inherent redundancy in complex-valued multi-channel MRI data. Our method leverages a provably optimal strategy for shrinking the singular values of a data matrix, allowing it to outperform state-of-the-art methods such as Marchenko-Pastur PCA in noise reduction. Our method reduces the noise floor in brain diffusion MRI by 5-fold and remarkably improves the contrast of spiral lung F MRI. Our framework is fast and does not require training and hyper-parameter tuning, therefore providing a convenient means for improving SNR in MRI.
Springer