Open reduction and internal fixation of intra-articular distal radius fractures under wide-awake local anesthesia with no tourniquet

H Orbach, N Rozen, G Rubin - Journal of International …, 2018 - journals.sagepub.com
H Orbach, N Rozen, G Rubin
Journal of International Medical Research, 2018journals.sagepub.com
Objective The use of wide-awake local anesthesia with no tourniquet (WALANT) is
becoming an excellent alternative for elective hand surgeries and hand surgeries involving
minor trauma. Although the use of WALANT for some soft tissue surgeries has become the
state of the art, data regarding bony procedures, such as fracture management, under
WALANT are limited. This study was performed to assess the WALANT technique for open
reduction and internal fixation of distal radius fractures. Methods Five patients with displaced …
Objective
The use of wide-awake local anesthesia with no tourniquet (WALANT) is becoming an excellent alternative for elective hand surgeries and hand surgeries involving minor trauma. Although the use of WALANT for some soft tissue surgeries has become the state of the art, data regarding bony procedures, such as fracture management, under WALANT are limited. This study was performed to assess the WALANT technique for open reduction and internal fixation of distal radius fractures.
Methods
Five patients with displaced distal radius fractures were enrolled in the study. WALANT was carried out about 30 minutes prior to the first incision. Surgery was performed in the normal fashion, and the fractures were fixed using anatomic locking plates. After surgery, the patients were admitted overnight for observation and pain assessment, and they were discharged within 24 hours postoperatively. Intraoperative and postoperative complications were recorded. Follow-up was performed in our outpatient clinic. No abnormalities were recorded.
Results
All patients underwent a successful painless surgery. No extra bleeding or other complications were recorded.
Conclusion
The WALANT technique offers a simple and safe alternative to traditional anesthetic techniques for open reduction and plating of distal radius fractures.
Sage Journals
以上显示的是最相近的搜索结果。 查看全部搜索结果