Polymer gel dosimetry

C Baldock, Y De Deene, S Doran, G Ibbott… - Physics in Medicine …, 2010 - iopscience.iop.org
Polymer gel dosimeters are fabricated from … polymer gel dosimetry is reviewed along with
the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are …

A systematic review of clinical applications of polymer gel dosimeters in radiotherapy

B Farhood, G Geraily, SMM Abtahi - Applied Radiation and Isotopes, 2019 - Elsevier
… application of polymer gel dosimeters in radiotherapy. In … of polymer gel dosimeters are
important for clinical applications? What are the characteristics of different polymer gel dosimeters

Essential characteristics of polymer gel dosimeters

Y De Deene - Journal of Physics: Conference Series, 2004 - iopscience.iop.org
… in a normoxic methacrylic acid based dosimeter gels (MAG polymer gel dosimeter) (figure
3b). In the case of the MAG polymer gel dosimeter, no gel-sol transition was observed at 30C. …

A basic study of some normoxic polymer gel dosimeters

Y De Deene, C Hurley, A Venning… - Physics in Medicine …, 2002 - iopscience.iop.org
polymer gel dosimeters. Basically, polymer gel dosimeters are composed of a gelatin gel in
which … Polymer gels in which acrylamide is used are called PAG or BANG-1R (BANG is the …

Radiological properties of normoxic polymer gel dosimeters

AJ Venning, KN Nitschke, PJ Keall… - Medical physics, 2005 - Wiley Online Library
… of true 3D dosimetry. For a polymer gel dosimeter to be of use in radiation dosimetry, it
should … within a given thickness or mass of polymer gel dosimeter should be the same as that …

Fundamentals of polymer gel dosimeters

KB McAuley - Journal of Physics: Conference Series, 2006 - iopscience.iop.org
… The recent literature on polymer gel dosimetry contains application papers and … gel dosimeters.
The basic studies assess the relative merits of these two most commonly used dosimeters

Dose–response stability and integrity of the dose distribution of various polymer gel dosimeters

Y De Deene, A Venning, C Hurley… - Physics in Medicine …, 2002 - iopscience.iop.org
… In this study the stability of different polymer gel dosimeters is investigated. Further to a
previous chemical stability study on a (6%T, 50%C) PAG gel, the change in slope and intercept of …

Ultrasound evaluation of polymer gel dosimeters

ML Mather, AK Whittaker… - Physics in Medicine & …, 2002 - iopscience.iop.org
… re-arrangements in the polymer gel dosimeter can lead to … in polymer gel dosimeters are
investigated with ultrasound. Acoustic parameters are evaluated for polymer gel dosimeters

Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging

AJ Venning, B Hill, S Brindha, BJ Healy… - Physics in Medicine & …, 2005 - iopscience.iop.org
… that the normoxic PAGAT polymer gel has the properties of a dosimetric tool, which can be
… The PAGAT polymer gel has been shown to have similar qualities to the PAG polymer gel, …

Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry

A Jirasek, M Hilts, KB McAuley - Physics in Medicine & Biology, 2010 - iopscience.iop.org
… Given that a single, complete 3D polymer gel dosimetry system has not been identified, work
has been undertaken in alternative imaging modalities for polymer gel dosimetry, including …