Design, characterization, and one-point in vivo calibration of a subcutaneously implanted glucose electrode

E Csoeregi, CP Quinn, DW Schmidtke… - Analytical …, 1994 - ACS Publications
… wire electrode for subcutaneous in vivo glucose monitoring, approaching in its performance
all of the above listed requirements, including in vivo one-point calibration. The electrode

Design and optimization of a selective subcutaneously implantable glucose electrode based on" wired" glucose oxidase

E Csoeregi, DW Schmidtke, A Heller - Analytical Chemistry, 1995 - ACS Publications
… The performance of the electrode when subcutaneously implanted in rats will be the subject
electrode (Figure 5), toshow that the subcutaneous electrode’s current tracked the glucose

Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?

K Rebrin, U Fischer, HH von Dorsche… - Journal of biomedical …, 1992 - Elsevier
electrodes and the effective duration of a given experiment were discernible. We conclude
that the functional bioinstability of subcutaneous glucose … of the electrodes; these drawbacks …

In vivo calibration of the subcutaneous amperometric glucose sensors using a non-enzyme electrode

RA Jeong, JY Hwang, S Joo, TD Chung, S Park… - Biosensors and …, 2003 - Elsevier
… the enzyme electrode in the subcutaneous tissue had a peak with about 10-min time delay
compared with the blood glucose level. It is believed that a push–pull mechanism for glucose

Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode

JG Wagner, DW Schmidtke, CP Quinn… - Proceedings of the …, 1998 - National Acad Sciences
… The capillary blood and the subcutaneous glucosesubcutaneous glucose concentration
was transiently higher. … ” glucose oxidase electrodes in a type I diabetic chimpanzee. …

In Vitro and In Vivo stability of electrode potentials in needle-type glucose sensors: Influence of needle material

G Velho, P Froguel, R Sternberg, DR Thevenot… - Diabetes, 1989 - Am Diabetes Assoc
… sensor and the reference electrode were implanted in the subcutaneous tissue through a …
variations in subcutaneous glucose levels induced by insulin injection and glucose infusion (n …

The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasma

W Kerner, M Kiwit, B Linke, FS Keck, H Zier… - Biosensors and …, 1993 - Elsevier
… hypothesize that inactivation of glucose electrodes in plasma and … signal of an amperometric
glucose electrode used for measurement of … In vivo measurement of subcutaneous glucose

Glucose sensing in the subcutaneous tissue: attempting to correlate the immune response with continuous glucose monitoring accuracy

JI Joseph, G Eisler, D Diaz, A Khalf… - Diabetes Technology …, 2018 - liebertpub.com
glucose sensor's needle and electrode through the epidermis and dermis into the subcutaneous
… The sensor's thin and flexible electrode remains within this region of subcutaneous

Electrocatalytic glucose sensor for subcutaneous application

K Lemke, R Lustermann - Bioelectrochemistry and bioenergetics, 1991 - Elsevier
… during adsorption, and also by direct catalytic decomposition of the glucose on the
platinum electrode. In accordance with the kinetic isothermals, the transient current decreases …

Performance of subcutaneously implanted glucose sensors for continuous monitoring

M Gerritsen, JA Jansen, JA Lutterman - The Netherlands journal of …, 1999 - Elsevier
… stated that all glucose electrodes based on glucose oxidase will require correction for oxygen
tension by a reference oxygen electrode. The fact that second generation glucose sensors, …