Urine protein-to-creatinine concentration ratio in samples collected by means of cystocentesis versus manual compression in cats

HCR Vilhena, RR Santos, TJ Sargo… - Journal of the …, 2015 - Am Vet Med Assoc
HCR Vilhena, RR Santos, TJ Sargo, TB Lima, SS Dias, MR Pastorinho, FL Queiroga
Journal of the American Veterinary Medical Association, 2015Am Vet Med Assoc
Objective—To compare urine protein-to-creatinine concentration (UPC) ratios in samples
collected by means of cystocentesis versus manual compression in cats. Design—
Evaluation study. Animals—43 client-owned cats requiring urinalysis. Procedures—In all
cats, 5 mL of urine from the midstream phase of micturition was collected by means of
manual compression and, subsequently, an additional 5 mL of urine was obtained by means
of ultrasound-guided cystocentesis. A complete urinalysis was performed on all samples …
Abstract
Objective —To compare urine protein-to-creatinine concentration (UPC) ratios in samples collected by means of cystocentesis versus manual compression in cats.
Design —Evaluation study.
Animals —43 client-owned cats requiring urinalysis.
Procedures —In all cats, 5 mL of urine from the midstream phase of micturition was collected by means of manual compression and, subsequently, an additional 5 mL of urine was obtained by means of ultrasound-guided cystocentesis. A complete urinalysis was performed on all samples, and UPC ratios were determined.
Results —Cats were classified on the basis of the International Renal Interest Society substaging system as being free from proteinuria (UPC ratio, < 0.2; n = 19) or as having borderline proteinuria (UPC ratio, 0.2 to 0.4; 7) or proteinuria (UPC ratio, > 0.4; 17). None of the cats had postrenal proteinuria. A significant linear correlation was identified between UPC ratios in urine samples obtained by means of manual compression and ratios in samples obtained by means of cystocentesis. For all cats, UPC ratios for samples obtained by the 2 collection methods resulted in classification in the same IRIS substage.
Conclusions and Clinical Relevance —Results suggested that collection of a urine sample from the midstream phase of micturition by manual compression would be a reliable alternative to cystocentesis for the determination of UPC ratio in cats, provided that postrenal proteinuria was excluded by means of urine sediment analysis. Once postrenal proteinuria was ruled out, the method used to collect urine samples did not appear to influence the quantification of urine protein concentration.