Utilization of target scattering to measure high-level electromagnetic fields: The MICHELSON method

S Vauchamp, M Lalande, J Andrieu… - IEEE Transactions …, 2010 - ieeexplore.ieee.org
S Vauchamp, M Lalande, J Andrieu, B Jecko, JL Lasserre, L Pecastaing, B Cadilhon
IEEE Transactions on Instrumentation and Measurement, 2010ieeexplore.ieee.org
The intention of this paper is to present the instantaneous electromagnetic field
measurement by signature of a neutral object (MICHELSON) method. The MICHELSON
method is relatively new and enables the measurement of high-level electromagnetic fields
from the utilization of a target. The incident field scattering on the target allows us to move
the field measurement to a new location where the scattered field can then be measured
using simple equipment and without breakdown risk. This method does away with the …
The intention of this paper is to present the instantaneous electromagnetic field measurement by signature of a neutral object (MICHELSON) method. The MICHELSON method is relatively new and enables the measurement of high-level electromagnetic fields from the utilization of a target. The incident field scattering on the target allows us to move the field measurement to a new location where the scattered field can then be measured using simple equipment and without breakdown risk. This method does away with the necessity for cables in the test zone. When using small targets, the induced disturbances in the incident field are limited. The MICHELSON method is implemented to characterize high-level electromagnetic sources whereby the signals radiated can be harmonic signals as well as transient pulses.
ieeexplore.ieee.org
以上显示的是最相近的搜索结果。 查看全部搜索结果