The ATLAS Inner Detector commissioning and calibration

Atlas Collaboration - arXiv preprint arXiv:1004.5293, 2010 - arxiv.org
… response to ionisation as a function of momentum and incident angle. … To measure the
resolution of the track parameters the cosmic-ray tracks which traverse the ATLAS detector from …

Total Ionising Dose effects in the FE-I4 front-end chip of the ATLAS Pixel IBL detector

K Dette - Journal of Instrumentation, 2016 - iopscience.iop.org
… The dependence of the current from the Total Ionising Dose (TID) and temperature has been
… the measurement results and gives a parameterisation of the leakage current and detector

Search for heavy, long-lived, charged particles with large ionisation energy loss in collisions at using the ATLAS experiment and the full Run 2 dataset

ATLAS collaboration - arXiv preprint arXiv:2205.06013, 2022 - arxiv.org
… particles with the ATLAS detector at the LHC using an integrated luminosity of 139 fb …
measurement assigned to each track is then calculated by averaging the ionisation measurements (…

Search for heavy charged long-lived particles in proton-proton collisions at root s= 13 TeV using an ionisation measurement with the ATLAS detector

ATLAS collaboration - 2019 - repository.arizona.edu
… a specific ionisation higher than any high-momentum Standard Model particle of unit charge.
The pixel subsystem of the ATLAS detector is used in this search to measure the ionisation

Characterisation and mitigation of beam-induced backgrounds observed in the ATLAS detector during the 2011 proton-proton run

ATLAS collaboration - arXiv preprint arXiv:1303.0223, 2013 - arxiv.org
… the read-out of the calorimeter cells that can be used to distinguish ionisation signals from
noise. The measured pulse is compared with the expectation from simulation of the electronics …

The ATLAS beam conditions monitor

V Cindro, D Dobos, I Dolenc, H Frais-Kölbl… - Journal of …, 2008 - iopscience.iop.org
… a measurement of bunch-by-bunch luminosities in ATLAS by … The ionisation charge however
is reduced by charge … the BCM detector modules and included it in the full ATLAS detector

[PS][PS] Performance of the ATLAS Muon Spectrometer

M Aleksa - 1999 - cds.cern.ch
… errors to the track-position measurement in one tube (eg … The ATLAS detector will be a
general-purpose proton-proton … the pulse, such measuring the drift time of the ionisation electrons. …

Measurement of the W-boson Polarisation in Top-Quark Decays with the ATLAS Detector

AH Knue - 2013 - inis.iaea.org
… The measurement presented in this thesis has been performed using the full 2011 ATLAS
… in this thesis has been collected with the ATLAS detector in 7 TeV proton-proton collisions at …

Search for heavy charged long-lived particles in proton-proton collisions at TeV using an ionisation measurement with the ATLAS detector

…, ATLAS collaboration - Phys. Lett. B 788 (2019) …, 2018 - digital.csic.es
… a specific ionisation higher than any high-momentum Standard Model particle of unit charge.
The pixel subsystem of the ATLAS detector is used in this search to measure the ionisation

Atlas itk pixel detector overview

L Meng - arXiv preprint arXiv:2105.10367, 2021 - arxiv.org
… upgrade of the ATLAS detector, the current Inner Detector (ID… dose at end-of-life with a high
rate, low rate of ionising … Middle: noise level of the modules measured warm and cold with …