[PDF][PDF] Analysis of body composition: a critical review of the use of bioelectrical impedance analysis

MS Mialich, JMF Sicchieri, AAJ Junior - Int J Clin Nutr, 2014 - academia.edu
… the analysis of body composition by bioelectrical impedance analysis, more popularly known
as bioimpedance analysis (BIA)… This method has been extensively used in studies of body

The use of bioelectrical impedance analysis for body composition in epidemiological studies

A Böhm, BL Heitmann - European journal of clinical nutrition, 2013 - nature.com
… in which fat accumulates in the body 1 and the body fat percentage (… , bioelectrical impedance
analysis (BIA) was introduced as a new method to be used for estimating body composition

Bioelectrical impedance analysis for body composition assessment: reflections on accuracy, clinical utility, and standardisation

LC Ward - European journal of clinical nutrition, 2019 - nature.com
Bioelectrical impedance analysis is an extremely popular method for assessment of body
composition. … and that different impedance analysers or prediction equations fail to measure …

Techniques used in the measurement of body composition: an overview with emphasis on bioelectrical impedance analysis

SB Heymsfield, Z Wang, M Visser, D Gallagher… - The American journal of …, 1996 - Elsevier
… relate to the five-level model and body-composition methods. We show how these concepts
… evaluate the bioelectrical impedance analysis method. Body-composition research is a …

Applications of bioelectrical impedance analysis for body composition to epidemiologic studies

R Roubenoff - The American journal of clinical nutrition, 1996 - Elsevier
Bioelectrical impedance analysis (BIA) is a promising tool in the evaluation of body composition
in … nature of the relation between resistance and reactance measured by BIA and body

Bioelectrical impedance analysis to assess body composition in obese adult women: the effect of ethnicity

JM Jakicic, RR Wing, W Lang - International journal of obesity, 1998 - nature.com
analyzed using Lunar DPX-L software version 1.3. Test-retest using DEXA to assess body
composition … meanÆstandard deviation) of 0.23Æ0.26% for percent body fat, 0.26Æ0.18kg for …

Bioelectrical impedance and body composition: present status and future directions

WC Chumlea, SS Guo - Nutrition Reviews, 1994 - academic.oup.com
… use of bioelectrical impedance in assessing body composition, it … some basic physical
information related to impedance. … the only body measures included in the present analysis. Other …

Bioelectrical impedance analysis—part I: review of principles and methods

…, C Pichard, Composition of the ESPEN Working Group - Clinical nutrition, 2004 - Elsevier
… This review discusses the application of bioelectrical impedance analysis (BIA). BIA is …
body mass. This implies three aspects for body composition analysis by the whole body BIA …

Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity

RF Kushner, A Kunigk, M Alspaugh, PT Andronis… - The American journal of …, 1990 - Elsevier
The bioelectrical-impedance-analysis (BIA) method accurately measures body composition
in weight-stable subjects. This study validates the use of BIA to measure change in body

Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans

D Bracco, D Thiebaud, RL Chiolero… - Journal of Applied …, 1996 - journals.physiology.org
body composition by bioelectrical impedance analysis and provides specific segmental
body composition … assessment of body composition plays an important role in nutritional …