Strategies for speed optimisation in gas chromatography: an overview

CA Cramers, PA Leclercq - Journal of Chromatography A, 1999 - Elsevier
… in gas chromatography. Extremely fast analysis is only possible when the required number of
plates to separate a critical … ) parameters, which characterise the chromatographic and flow …

Critical reconsideration of the physical meaning and the use of fundamental retention parameters in gas chromatography. New IUPAC recommendations

VA Davankov - Chromatographia, 2003 - Springer
The term „corrected retention volume”V R o was introduced by Martin and James in 1952
and is the most important retention parameter in gas chromatography. Its calculation involves …

Sources of uncertainty in gas chromatography and high-performance liquid chromatography

VJ Barwick - Journal of Chromatography A, 1999 - Elsevier
… analysis by gas chromatography (GC) and high-performance liquid chromatography (HPLC).
It … In addition, a number of authors have discussed the critical parameters and potential …

High-speed gas chromatography: an overview of various concepts

CA Cramers, HG Janssen, MM van Deursen… - … of chromatography A, 1999 - Elsevier
gas chromatography. Extremely fast analysis is only possible when the required number of
plates to separate a critical … plate height upon carrier gas velocity and column parameters, eg, …

Inverse gas chromatography for natural fibre characterisation: Identification of the critical parameters to determine the Brunauer–Emmett–Teller specific surface area

A Legras, A Kondor, MT Heitzmann… - Journal of Chromatography …, 2015 - Elsevier
… Inverse gas chromatography is an alternative tool to study surface energies. IGC is based
on solid–gas interactions and the affinity between gas probe molecules and the fibre surface …

Application of inverse gas chromatography and regular solution theory for characterization of ionic liquids

F Mutelet, V Butet, JN Jaubert - Industrial & engineering chemistry …, 2005 - ACS Publications
Critical parameters and acentric factors used for the calculations were taken from the … how
inverse gas chromatography can be used to determine the thermodynamic parameters that …

[HTML][HTML] Gas chromatography–mass spectrometry data processing made easy

LG Johnsen, PB Skou, B Khakimov, R Bro - Journal of Chromatography A, 2017 - Elsevier
parameter to be set by the user prior to achieving sufficient data processing for the given
retention time region of the chromatogram… user but this is mostly not critical. Once the model for …

Column selection and optimization for comprehensive two-dimensional gas chromatography: a review

J Mommers, S van der Wal - Critical reviews in analytical chemistry, 2021 - Taylor & Francis
… A critical parameter of a loop-type modulator is the length of the delay loop. The length
should not be too long, to ensure that analytes are trapped and focused by the downstream cold …

Critical review and re-assessment of analyte protectants in gas chromatography

R Rodríguez-Ramos, SJ Lehotay, N Michlig… - … of Chromatography A, 2020 - Elsevier
… This article consists of a critical review of the scientific literature, proposal of mechanisms
and theory, and re-evaluation studies involving APs for the first time in GC-orbitrap and GC–MS/…

Micro gas chromatography: An overview of critical components and their integration

BP Regmi, M Agah - Analytical chemistry, 2018 - ACS Publications
… , a miniaturized version of gas chromatography (GC) system is a … , we use the term “micro
gas chromatograph” (μGC) to refer any … Another important parameter that is commonly used to …