Elution order in gas chromatography

M Mehran, WJ Cooper, N Golkar… - … Chromatography, 1991 - Wiley Online Library
… The retention behavior of a heterogeneous group of solutes … and carrier gas velocity were
shown to affect solute elution order. … studies based on solute elution order have dubious value. …

Elution behavior of chemically different probes on the evaluation of surface properties of cellulose by inverse gas chromatography

G Czeremuszkin, P Mukhopadhyay… - Journal of colloid and …, 1997 - Elsevier
… longed trapping phenomenon or incomplete elution of probe molecules in the adsorbent …
probes from their elution behavior by latter effect form typical retention behavior normally seen …

A different operational mode for addressing the general elution problem in rapid analysis gas chromatography

WA Rubey - Journal of High Resolution Chromatography, 1991 - Wiley Online Library
… mode, designated thermal gradient programmed gas chromatography (TGPGC), can perform
behavior relative to axial length of solutezonefordifferent modes of gas chromatography. …

Elution behavior of model compounds in gel permeation chromatography

GD Edwards, QY Ng - Journal of Polymer Science Part C …, 1968 - Wiley Online Library
… or unstable under gas chromatography conditions. … the emergence of solutes during
chromatography. Hendrickson and … shall now describe the elution behavior of the model …

Elution parameters in constant-pressure, single-ramp temperature-programmed gas chromatography

LM Blumberg, MS Klee - Journal of Chromatography A, 2001 - Elsevier
… In this study, we evaluate the values, k e , λ e and μ e , of k, λ and μ at the time of solute
elution from the column in temperature programmed GC (gas chromatography). …

Elution behavior of polyethylene in polar mobile phases on a non-polar sorbent

T Macko, H Pasch, YV Kazakevich… - Journal of Chromatography …, 2003 - Elsevier
… In gas chromatography, dimethylsiloxane columns are used for the separation of alkanes.
Separation of alkanes in these columns is very selective [22]. A new highly hydrophobic …

Elution Time and Resolution in Vapor Chromatography.

AK Wiebe - The Journal of Physical Chemistry, 1956 - ACS Publications
… carrier gas flow rate. However, theory derived for liquid phase systems can be applied to
gas chromatography provided the necessary cor- rections for carrier gas compressibility are …

Evaluation of the linear-elution-strength model for the prediction of retention and selectivity in isothermal gas chromatography

MI Nawas, CF Poole - Chromatographia, 2004 - Springer
… the DryLabÒ software for method development in gas chromatography [8– 10]. Here, it is
assumed that retention in isothermal gas chromatography is related to temperature by Eq. (1) …

Thermodynamics of Multilayer Adsorption Studied by Elution Gas Chromatography

S Masukawa, R Kobayashi - Journal of Chromatographic …, 1968 - academic.oup.com
… Recent refinements have been made to the elution gas chromatographic technique for the …
monolayer adsorption of a binary gas mixture (1,2) and to the adsorption of a gas on a liquid (3…

… model of nonlinear gas chromatography for the modelling of the elution band profiles in the preparative-scale gas chromatographic separation of enantiomers

DU Staerk, A Shitangkoon, E Winchester, G Vigh… - … of Chromatography A, 1996 - Elsevier
… of chromatography is applied to the study of enantioselective separations of methyl 2-chloropropionate
in gas chromatography. … that describe the sorption behavior of single enantiomers …