Design and test of tuned liquid mass dampers for attenuation of the wind responses of a full scale building

KW Min, J Kim, YW Kim - Smart materials and structures, 2014 - iopscience.iop.org
… behavior of the TMD and TLCD for a full scale building. … The TLMD is a damper that behaves
as a TLCD in one specific … , namely a laboratory scale model and a full scale five story steel …

Real‐time hybrid aeroelastic simulation of wind turbines with various types of fullscale tuned liquid dampers

Z Zhang, B Basu, SRK Nielsen - Wind Energy, 2019 - Wiley Online Library
… a full-scale testing of the above-mentioned fluid-structure interaction problem and turns out to
be an ideal tool for investigating the performance of liquid dampers … RTHS, full-scale testing …

Experimental determination of structural damping of a fullscale building with and without tuned liquid dampers

M Tarpø, C Georgakis, A Brandt… - Structural Control and …, 2021 - Wiley Online Library
… The reader should note that the term “tuned sloshing dampers” is often used interchangeable
with “tuned liquid dampers,” 7 and this paper uses the term tuned liquid damper. Here, the …

Performance evaluation of full-scale tuned liquid dampers (TLDs) for vibration control of large wind turbines using real-time hybrid testing

Z Zhang, A Staino, B Basu, SRK Nielsen - Engineering Structures, 2016 - Elsevier
… Tuned liquid dampers (TLDs) … of full scale TLDs to control vibration of such special facilities
like wind turbine towers are absent in literature. In this paper, the performance of a full-scale

Real-time hybrid simulation of full-scale tuned liquid column dampers to control multi-order modal responses of structures

F Zhu, JT Wang, F Jin, LQ Lu - Engineering Structures, 2017 - Elsevier
… This paper aims to demonstrate the real performance of tuned liquid column dampers (TLCDs)
in … An RTHS framework is developed to carry out full-scale experiments of TLCD-structure-…

Effectiveness of tuned liquid dampers under wind excitation

Y Tamura, K Fujii, T Ohtsuki, T Wakahara… - Engineering …, 1995 - Elsevier
damper utilizing liquid has been used for satellite spin stabilization L2. The first proposal to
apply the liquid damper … , where it was named 'a nutation damper'. The TLD absorbs vibration …

Real‐time hybrid simulation of the size effect of tuned liquid dampers

F Zhu, JT Wang, F Jin, LQ Lu, Y Gui… - Structural Control and …, 2017 - Wiley Online Library
damper on the seismic control of single degree-of-freedom (SDOF) structures. In this paper,
by taking advantage of RTHS in full-scale … According to the full scale experiment scheme in …

Dynamic parameter identification of secondary mass dampers based on fullscale tests

BH Cho, JS Jo, SJ Joo, H Kim - Computer‐Aided Civil and …, 2012 - Wiley Online Library
… mass damper such as tuned liquid damper (TLD) or tuned liquid column damper (TLCD),
whose moving mass is liquid, it is impossible to prefabricate the damper in a factory for the …

[HTML][HTML] Investigating Large-Scale Tuned Liquid Dampers through Real-Time Hybrid Simulations

A Ashasi Sorkhabi, B Qiu, O Mercan - Buildings, 2024 - mdpi.com
… This study has provided insights into the performance of tuned liquid dampers in suppressing
vibrations of structures under seismic loading conditions. Through a series of real-time …

On the current status of magnetorheological dampers: seismic protection of full-scale structures

BF Spencer, JD Carlson, MK Sain… - Proceedings of the 1997 …, 1997 - ieeexplore.ieee.org
… and robustness, magnetorheological (MR)fluid dampers have been shown to be semi-active …
, scale-model building and preliminary analyses of a prototype full-scale MR damper. …