Critical reconsideration of the physical meaning and the use of fundamental retention parameters in gas chromatography. New IUPAC recommendations

VA Davankov - Chromatographia, 2003 - Springer
The term „corrected retention volume”V R o was introduced by Martin and James in 1952
and is the most important retention parameter in gas chromatography. Its calculation involves …

Strategies for speed optimisation in gas chromatography: an overview

CA Cramers, PA Leclercq - Journal of Chromatography A, 1999 - Elsevier
… in gas chromatography. Extremely fast analysis is only possible when the required number of
plates to separate a critical … ) parameters, which characterise the chromatographic and flow …

Sources of uncertainty in gas chromatography and high-performance liquid chromatography

VJ Barwick - Journal of Chromatography A, 1999 - Elsevier
… on the key parameters that affect analysis by gas and liquid … authors have discussed the
critical parameters and potential … Jennings and Mehran [20] identify the critical parameters for …

High-speed gas chromatography: an overview of various concepts

CA Cramers, HG Janssen, MM van Deursen… - … of chromatography A, 1999 - Elsevier
gas chromatography. Extremely fast analysis is only possible when the required number of
plates to separate a critical … plate height upon carrier gas velocity and column parameters, eg, …

Application of inverse gas chromatography and regular solution theory for characterization of ionic liquids

F Mutelet, V Butet, JN Jaubert - Industrial & engineering chemistry …, 2005 - ACS Publications
parameter and Hansen's solubility parameter of the three RTILs by inverse gas chromatography
Critical parameters and acentric factors used for the calculations were taken from the …

Gas chromatography–mass spectrometry data processing made easy

LG Johnsen, PB Skou, B Khakimov, R Bro - Journal of Chromatography A, 2017 - Elsevier
… only requires a single parameter to be set by the user prior to achieving sufficient data
processing for the given retention time region of the chromatogram. This parameter is the number …

Inverse gas chromatography for natural fibre characterisation: Identification of the critical parameters to determine the Brunauer–Emmett–Teller specific surface area

A Legras, A Kondor, MT Heitzmann… - Journal of Chromatography …, 2015 - Elsevier
… Inverse gas chromatography is an alternative tool to study surface energies. IGC is based
on solid–gas interactions and the affinity between gas probe molecules and the fibre surface …

Column selection and optimization for comprehensive two-dimensional gas chromatography: a review

J Mommers, S van der Wal - Critical reviews in analytical chemistry, 2021 - Taylor & Francis
… A critical parameter of a loop-type modulator is the length of the delay loop. The length
should not be too long, to ensure that analytes are trapped and focused by the downstream cold …

High-speed gas chromatography with direct resistively-heated column (ultra fast module-GC)-separation measure (S) and other chromatographic parameters under …

C Bicchi, C Brunelli, C Cordero, P Rubiolo… - … of Chromatography A, 2005 - Elsevier
The influence of GC speed on the separation capability of a chromatographic system is
reported measuring a series of parameters including separation measure (S), peak capacity (n), …

[图书][B] Basic gas chromatography

HM McNair, JM Miller, NH Snow - 2019 - books.google.com
… He is widely published in gas chromatography and has been teaching GC to new students
… As such, it is just as valuable a parameter as the distribution constant, and it is one that can …