Blind bolting W-shape beams to HSS columns

RM Korol, A Ghobarah, S Mourad - Journal of Structural …, 1993 - ascelibrary.org
… end-plate connection as proposed for a W-shape beam and HSS column that utilizes high-strength
blind bolts appears to be very promising as an effective moment connection in steel …

Moment-rotation relationship of blind bolted connections for HSS columns

A Ghobarah, S Mourad, RM Korol - Journal of Constructional Steel …, 1996 - Elsevier
… the bolt's head and the inner face of the HSS column flange. If the column flange thickness
is not sufficient to resist the maximum bolt's tensile strength, a shear failure of the column

11 BEHAVIOUR OF BLIND BOLTED MOMENT CONNECTIONS FOR HSS COLUMNS

A Ghobarah, S Mourad, RM Korol - Tubular Structures V, 2004 - books.google.com
… in practical bolted moment connections with square columns, … then to bolt the plate to the
flange of the HSS column in the … -site bolting, hallmarks for good quality control and economy. …

Development of mathematical model for cyclic behaviour of blind bolted HSS column components

ZY Wang, X Yang, QY Wang, Y Liu - Archives of Civil and Mechanical …, 2017 - Elsevier
… component of HSS column under bolt tension load is the … connected at opposite sides of
HSS column so as to ensure the … flexibility of the HSS column wall and tension of the bolt as the …

I-beam to square hollow column blind bolted moment connection: Experimental and numerical study

MM Tahir, H Mohammadhosseini, SP Ngian… - … of Constructional Steel …, 2018 - Elsevier
… of moment connection for HSS column using different types of blind bolts have been … blind
bolted extended end plate connections with high strength blind bolts (HSBB) in HSS columns. …

Yield and ultimate strengths determination of a blind bolted endplate connection to square hollow section column

ZY Wang, QY Wang - Engineering structures, 2016 - Elsevier
… Although this model was also suggested [21] and referred [30] in an analogical design
strength prediction of the bolted connections to HSS columns, no further consideration was given …

Thermal behaviour of blind-bolted connections to hollow and concrete-filled steel tubular columns

AM Pascual, ML Romero, W Tizani - Journal of Constructional Steel …, 2015 - Elsevier
… of blind-bolts connected to concrete filled steel tube (CFST) and hollow steel section (HSS)
columns. … with the thermal analysis of blind-bolts in endplate connections to HSS and CFST …

Shear capacity of blind bolted connections for RHS steel structural elements

M Ballerini, M Piazza, E Bozzo, F Occhi - Tubular Structures VII, 2022 - taylorfrancis.com
… -Bolt blind bolting systems are analysed and compared with the results of traditional bolting
… These results concern both simple and full-scale beam-to-column connections, with bolts in …

[PDF][PDF] Experimental study on modified blind bolts anchored in concrete-filled steel tubular columns

H Yao, H Goldsworthy, E Gad… - Proc., Australian …, 2011 - researchbank.swinburne.edu.au
… the columns and beams using normal blind bolts are limited … blind bolts bearing on the inside
of the tube wall. This paper reports the results of an innovative modified version of blind bolt

Experimental and analytical behavior of blind bolted moment connections

J Wang, BF Spencer Jr - Journal of Constructional Steel Research, 2013 - Elsevier
blind bolted connections for HSS columns, which included T-stub connection, channel side
plate connection and channel T-stub connection. France et al. [7], [8], [9] conducted a series …