Dynamic parameter identification of secondary mass dampers based on fullscale tests

BH Cho, JS Jo, SJ Joo, H Kim - Computer‐Aided Civil and …, 2012 - Wiley Online Library
… concrete tuned mass damper (TMD), whose moving mass is … of secondary mass dampers
based on the full-scale field test is … of motion of building and damper. The decoupled equations …

Design and test of tuned liquid mass dampers for attenuation of the wind responses of a full scale building

KW Min, J Kim, YW Kim - Smart materials and structures, 2014 - iopscience.iop.org
scale model and a full scale five story steel building. A uniaxial shaking table and a hybrid
mass … First, a prototype TLMD is used for the uniaxial shaking table test. The result shows that …

[PDF][PDF] Full-scale dynamic tests and analytical verification of a force-restricted tuned viscous mass damper

Y Watanabe, K Ikago, N Inoue, H Kida… - 15th World Conference …, 2012 - iitk.ac.in
damper mechanism by using rotational friction. Full-scale dynamic tests were conducted using
a full-scale … apparent inertial mass of 5400 t, and force limits of 600 kN and 2000 kN. The …

Full-scale shake table tests of a reinforced concrete building equipped with a novel servo-hydraulic active mass damper

G Rebecchi, PM Calvi, A Bussini… - Journal of Earthquake …, 2023 - Taylor & Francis
… shake table testing of two full-scale reinforced concrete frame buildings. These tests were …
of a newly proposed servo-hydraulic Active Mass Damper (AMD) that can be designed to …

Modelling of tuned mass dampers for wind-tunnel tests on a full-bridge aeroelastic model

GL Larose, A Larsen, E Svensson - Journal of wind engineering and …, 1995 - Elsevier
… dec.), a natural frequency set to 99% of the mode to be damped and a possible peak
displacement equivalent to 1 m full scale. Fig. 5 gives the overall dimensions of the model TMDs, …

Vibration mitigation of stay cables using electromagnetic inertial mass dampers: Full-scale experiment and analysis

Y Li, W Shen, H Zhu - Engineering Structures, 2019 - Elsevier
… a full-scale experimental study on the vibration mitigation of a 135 m long cable using a
prototype EIMD. A series of free vibration tests … inherent damping ratio of the test cable are 1.060 …

Experimental determination of structural damping of a fullscale building with and without tuned liquid dampers

M Tarpø, C Georgakis, A Brandt… - Structural Control and …, 2021 - Wiley Online Library
damping and the effect that the tuned liquid dampers have on this. Two different full-scale
test … information to the database of tall building damping characteristics and full scale tests. …

Feasibility study of a large-scale tuned mass damper with eddy current damping mechanism

Z Wang, Z Chen, J Wang - Earthquake Engineering and Engineering …, 2012 - Springer
… This paper discusses the design, analysis, manufacture and testing of a large-scale
horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one …

Seismic response of full-scale structure with added viscoelastic dampers

KC Chang, YY Lin - Journal of Structural Engineering, 2004 - ascelibrary.org
test and analytical results of a full-scale 5 story steel frame with added viscoelastic (VE)
dampers… the effectiveness of applying the VE dampers to full-scale structures, this study also …

Experimental and analytical study on design performance of full-scale viscoelastic dampers

SJ Wang, IC Chiu, CH Yu, KC Chang - Earthquake Engineering and …, 2018 - Springer
… represent the actual behavior of full-scale dampers, especially with regard to the … testing
facility with a temperature control system, full-scale VE dampers were dynamically tested with …