End‐to‐end verification of an MRLinac using a dynamic motion phantom

X Liu, C Li, J Zhu, G Gong, H Sun, X Li, M Sun… - Medical …, 2021 - Wiley Online Library
motion patterns to test phantomMR compatible dynamic phantom to verify the adaptive
planning and delivery accuracy for a new MR-Linac with different adaptive workflows and motion

3D motion validation with clinically used cine-MRI and a MR-LINAC phantom

K Dolde, S Schneider, A Pfaffenberger… - Radiotherapy and …, 2018 - hzdr.de
MRmotion tracking through MR-imaging needs to be assessed. In this study we evaluate
the dynamic target localization accuracy of a programmable MRI-compatible motion phantom

First demonstration of intrafractional tumor‐tracked irradiation using 2D phantom MR images on a prototype linacMR

J Yun, K Wachowicz, M Mackenzie, S Rathee… - Medical …, 2013 - Wiley Online Library
MR compatible motion phantom to simulate tumor motions during tracking with two different
motion … Gafchromic film was inserted in the phantom to measure radiation exposure, and this …

Clinical experience of MRI4D QUASAR motion phantom for latency measurements in 0.35T MRLINAC

T Kim, B Lewis, R Lotey, E Barberi… - Journal of applied …, 2021 - Wiley Online Library
… In this report, clinical experience of the MRI 4D QUASAR motion phantom for latency
measurements on a 0.35-T magnetic resonance-linear accelerator (MR-LINAC) with two imaging …

Real‐time motion monitoring using orthogonal cine MRI during MR‐guided adaptive radiation therapy for abdominal tumors on 1.5 T MRLinac

H Jassar, A Tai, X Chen, TD Keiper, E Paulson… - Medical …, 2023 - Wiley Online Library
… treated with the 1.5T MR-Linac. We demonstrated the use of … the reference MidP-MR
reduced the motion artifact that could … Such accurate monitoring/measuring the target motion on …

Tumor trailing for liver SBRT on the MR-Linac

M Fast, A van de Schoot, T van de Lindt… - International Journal of …, 2019 - Elsevier
… : 5 minutes), or (4) MR imaging–measured baseline drifts. … motion interplay. In addition,
trailing was experimentally validated on the MR-Linac using a programmable motion phantom

First experimental investigation of simultaneously tracking two independently moving targets on an MRI‐linac using real‐time MRI and MLC tracking

PZY Liu, B Dong, DT Nguyen, Y Ge… - Medical …, 2020 - Wiley Online Library
… Once latency was accounted for, the accuracy of template matching was defined as the RMSE
between the position reported by the motion phantom and the position calculated from MR

Dosimetric Assessment for Real-Time Anatomical Motion during MR-Guided Radiation Therapy by MR-LINAC

X Chen, S Oh, MS Hwang, D Lee, R Fuhrer… - International Journal of …, 2022 - redjournal.org
… during dose delivery was captured by 2D monitoring MR … then registered to the 3D planning
MR images (pMR) of the … to the commissioning data in water phantom with difference <1% …

[HTML][HTML] Prostate intrafraction motion during the preparation and delivery of MR-guided radiotherapy sessions on a 1.5 T MR-Linac

DM de Muinck Keizer, LGW Kerkmeijer… - Radiotherapy and …, 2020 - Elsevier
… Validation using motion phantom … on the cine-MR dynamics as acquired on our MR-Linac
system, we made use of a programmable motion phantom (Modus QA, Quasar 4D MRI motion

Feasibility of real‐time motion tracking using cine MRI during MR‐guided radiation therapy for abdominal targets

TD Keiper, A Tai, X Chen, E Paulson… - Medical …, 2020 - Wiley Online Library
… tracking based on the registration of MRI acquired on MR-Linac. … The tracking degradation
with respect to the AP motion is evident in our XCAT phantom results presented in Table II. …