Picosecond phase fluorometry by mode-locked CW lasers

K Berndt, H Duerr, D Palme - Optics Communications, 1982 - Elsevier
A new picosecond to nanosecond phase fluorometer is reported for measurements of
fluorescence lifetime τ f and rotational diffusion time constants τ rot which uses a mode …

Phase fluorometer for measurement of picosecond processes

HP Haar, M Hauser - Review of Scientific Instruments, 1978 - pubs.aip.org
Investigations of fluorescence processes in the picosecond time scale can be done using
short light pulses, as generated by a mode locked laser, or using continuous but sinusoidally …

Phase-resolved subnanosecond spectroscopy using the beat frequencies from mode-locked lasers

MJ Wirth, SH Chou - Applied spectroscopy, 1988 - opg.optica.org
It is shown that the beat frequencies inherent to a mode-locked dye laser can be used in
phase fluorometry. The fluorescence lifetime of cresyl violet, quenched by KI, is determined …

Picosecond‐resolution fluorescence lifetime measuring system with a cw laser and a radio

ER Menzel, ZD Popovic - Review of Scientific Instruments, 1978 - pubs.aip.org
A procedure for measurement of fluorescence lifetimes with picosecond time resolution is
described. A cw laser beam is modulated with a standing-wave acousto-optic modulator …

[引用][C] Measurement of nanosecond fluorescence decay times

ME Mack - Journal of Applied Physics, 1968 - pubs.aip.org
To observe a fluorescent decay a high-intensity source having a rapid fall time is required to
excite the fluorescence and a widebandwidth detection system is needed to detect it. Mode …

Phase fluorometry using a continuously modulated laser diode

RB Thompson, JK Frisoli, JR Lakowicz - Analytical chemistry, 1992 - ACS Publications
The authors report phase fluorometrlc measurements using directly amplitude-modulated
670-and 791-nm laser diodes as the excitation source. Fluorescence lifetimes ranging from …

Fluorescence lifetime resolution with phase fluorometry

G Ide, Y Engelborghs, A Persoons - Review of Scientific Instruments, 1983 - pubs.aip.org
A phase fluorometer for the measurement of fluorescence lifetimes was constructed from
commercially available components. The instrument was tested by using optical delays of 4 …

A new fiber-optic-based multifrequency phase-modulation fluorometer

FV Bright - Applied spectroscopy, 1988 - opg.optica.org
A new fiber-optic-based fluorescence lifetime instrument is described which is useful for the
study of complex fluorescence decay kinetics. The new instrument consists of a …

Phase‐modulation fluorometry using a frequency‐doubled pulsed laser diode light source

KW Berndt, I Gryczynski, JR Lakowicz - Review of scientific instruments, 1990 - pubs.aip.org
We describe the use of a pulsed frequency‐doubled laser diode, the Hamamatsu model
PLP‐01 picosecond light pulser, as a 413‐nm excitation light source for frequency‐domain …

Remote sensing with a multifrequency phase-modulation fluorometer

FV Bright - Time-Resolved Laser Spectroscopy in Biochemistry, 1988 - spiedigitallibrary.org
A new fiber-optic-based fluorescence lifetime instrument is described. The new instrument
consists of a multifrequency cross-correlation phase-modulation fluorometer and a fiber …