Experimental limitations in impedance spectroscopy: Part I—simulation of reference electrode artifacts in three-point measurements

G Hsieh, SJ Ford, TO Mason, LR Pederson - Solid State Ionics, 1996 - Elsevier
Impedance studies on test circuits demonstrated that three-point measurements are
susceptible to voltage divider distortion/artifacts if the reference electrode impedance …

Experimental limitations in impedance spectroscopy: Part VI. Four-point measurements of solid materials systems

G Hsieh, SJ Ford, TO Mason, LR Pederson - Solid State Ionics, 1997 - Elsevier
Four-point impedance spectroscopy of solid materials systems is severely hampered by
unavoidable voltage-divider effects associated with the reference electrodes. As …

The use of voltage probes in impedance spectroscopy

G Fafilek - Solid State Ionics, 2005 - Elsevier
In electrochemical impedance spectroscopy, a reference electrode is often used for the
control of the potential of a working electrode by means of a potentiostat in a 3-electrode …

Experimental limitations in impedance spectroscopy: Part III. Effect of reference electrode geometry/position

G Hsieh, TO Mason, EJ Garboczi, LR Pederson - Solid State Ionics, 1997 - Elsevier
Experiments and computer simulations on Pt/YSZ specimens in various electrode
configurations were performed to investigate the effect of reference electrode …

Experimental limitations in impedance spectroscopy:: Part V. Apparatus contributions and corrections

DD Edwards, JH Hwang, SJ Ford, TO Mason - Solid State Ionics, 1997 - Elsevier
Overlooked apparatus (cabling, leads, sample holder) contributions to experimental
impedance spectra can be significant, especially at high frequencies, and can obscure the …

Understanding artifacts in impedance spectroscopy

BW Veal, PM Baldo, AP Paulikas… - Journal of the …, 2014 - iopscience.iop.org
Four-terminal measurements of impedance spectra have long been troubled by the
presence of high frequency artifacts that typically indicate unphysically large inductive …

Experimental limitations in impedance spectroscopy: Part II—electrode artifacts in three-point measurements on Pt/YSZ

G Hsieh, TO Mason, LR Pederson - Solid State Ionics, 1996 - Elsevier
High temperature (570–750° C) three-point impedance measurements on the system Pt/YSZ
using a platinum reference electrode exhibited distortions/artifacts due to the voltage divider …

Inductive loops in impedance spectroscopy caused by electrical shielding

J Fleig, J Jamnik, J Maier, J Ludvig - Journal of the …, 1996 - iopscience.iop.org
The electrical shielding of the sample which is inevitable for the measurement of high
impedances can lead to significant anomalies in the measured impedance. The …

Impedance spectroscopy: old problems and new developments

JR Macdonald - Electrochimica Acta, 1990 - Elsevier
The generality, scope, and limitations of Impedance Spectroscopy (IS) are discussed, with
emphasis on unsupported conditions in ionic systems. For such conditions, the maximum …

[引用][C] Application of impedance spectroscopy to materials science

ID Raistrick - Annual Review of Materials Science, 1986 - annualreviews.org
In this article the term" impedance spectroscopy" is used to describe any technique in which
data, equivalent to the real and imaginary parts of a complex electrical quantity, are …