Comparison of different optimized irregular sparse 2D ultrasound arrays

B Diarra, E Roux, H Liebgott, S Ravi… - 2016 IEEE …, 2016 - ieeexplore.ieee.org
The role of 2D matrix arrays in the realization of real time 3D ultrasound imaging is crucial as
the latter permit to acquire a complete volume. The lack of control systems for these arrays …

Variable-size elements in 2D sparse arrays for 3D medical ultrasound

B Diarra, M Robini, H Liebgott… - 2013 IEEE …, 2013 - ieeexplore.ieee.org
The sparse array technique is an excellent approach to tackle the connection difficulties due
to the huge number of elements of 2D matrix arrays. However, the reduction of the element …

Validation of optimal 2D sparse arrays in focused mode: Phantom experiments

E Roux, E Badescu, L Petrusca, F Varray… - 2017 IEEE …, 2017 - ieeexplore.ieee.org
There is an increasing interest for sparse 2D arrays as an alternative to full gridded arrays
used in commercial systems. This work presents an effective and straightforward solution to …

Spiral array inspired multi-depth cost function for 2D sparse array optimization

E Roux, A Ramalli, M Robini, H Liebgott… - 2015 IEEE …, 2015 - ieeexplore.ieee.org
Matrix sparse array optimization for 3D ultrasound imaging often uses simulated annealing
(SA) algorithms to reduce the number of elements and to find their best position, intensity …

Study and optimization of 2D matrix arrays for 3D ultrasound imaging

B Diarra - 2013 - theses.hal.science
3D Ultrasound imaging is a fast-growing medical imaging modality. In addition to its
numerous advantages (low cost, non-ionizing beam, portability) it allows to represent the …

Optimization of free-moving elements in 2D ultrasound sparse arrays

B Diarra, M Robini, E Roux, H Liebgott… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
The non-grid sparse array technique is a promising approach to overcome the connection
difficulties of 2D matrix arrays and to partially compensate the energy loss linked to the …

Improved beamforming using curved sparse 2D arrays in ultrasound

JE Kirkebø, A Austeng - Ultrasonics, 2007 - Elsevier
In this work we have investigated the effect of curving phase-steered sparse periodic two-
dimensional arrays in one direction, and relate this effect to the geometry of the arrays. We …

Aperture and element minimization in linear sparse arrays with desired beam patterns

A Trucco - Ultrasonics, 2000 - Elsevier
In this paper, an optimization method aimed at designing aperiodic linear sparse arrays is
proposed that is based on the stochastic optimization methodology called simulated …

Sparse arrays for real-time 3D imaging, simulated and experimental results

A Austeng, S Holm - 2000 IEEE Ultrasonics Symposium …, 2000 - ieeexplore.ieee.org
This work presents the outputs from a project which aimed to lay the foundation of a 3D
ultrasound imaging system where the emphasis was on real-time data acquisition and near …

Non-grid based elements positioning for optimal 2D array beams

B Diarra, H Liebgott, C Cachard… - 2012 IEEE International …, 2012 - ieeexplore.ieee.org
2D matrix probes present a real capability for three dimensional ultrasound imaging. The
main difficulties to implement these probes come from the need of using a huge number of …