Optimal Orientation Angle Configuration of Polarizers Exists in a 3× 3 Mueller Matrix Polarimeter

H Wei, Y Zhou, L Ren, F Ma - Photonics, 2023 - mdpi.com
A 3× 3 Mueller matrix polarimeter, as one of the primary polarization measurement tools, has
attracted intensive interest in various fields of polarization optics. In this paper, from a novel …

Analysis of experimental errors in Mueller matrix channeled polarimeters

LO González-Siu, NC Bruce - Applied Optics, 2021 - opg.optica.org
This work analyzes the effect of experimental errors and measurement noise on Mueller
matrix channeled spectropolarimeters. The main advantage of this type of polarimeter is the …

Permitted experimental errors for optimized variable-retarder Mueller-matrix polarimeters

NC Bruce, JM López-Téllez, O Rodríguez-Núñez… - Optics …, 2018 - opg.optica.org
An optimized Mueller-matrix polarimeter is simulated. The polarimeter is optimized by
finding the configurations of the polarization state generator and polarization state analyzer …

Extended eigenvalue calibration method for overdetermined Mueller matrix polarimeters

SA Rosales, EG Caurel, R Ossikovski - Optics Letters, 2024 - opg.optica.org
The eigenvalue calibration method is a versatile approach that can be applied to any type of
the Mueller matrix polarimetic setup because a precise knowledge of the optical response of …

Validity of the product rule and its impact on the accuracy of a Mueller matrix polarimeter

E Chironi, C Iemmi - Applied Optics, 2021 - opg.optica.org
In this work, we analyze the validity of the product rule and its impact on the accuracy of a
Mueller matrix polarimeter. We demonstrate that the validity of the rule is essential to perform …

High precision calibration method for a four-axis Mueller matrix polarimeter

J del Hoyo, LM Sanchez-Brea… - Optics and Lasers in …, 2020 - Elsevier
We present a novel method for calibrating a four-axis Mueller matrix polarimeter. This
method is valid even for non-ideal optical elements, as it models all polarization elements …

Polarizer calibration method for Mueller matrix polarimeters

R Ossikovski, B Al Bugami, E Garcia-Caurel… - Applied …, 2020 - opg.optica.org
We advance what we believe is a novel eigenvalue-based method for calibrating Mueller
matrix polarimeters employing a single calibration optical component: a polarizer. The …

Optimization of Mueller matrix polarimeters in the presence of error sources

KM Twietmeyer, RA Chipman - Optics Express, 2008 - opg.optica.org
Methods are presented for optimizing the design of Mueller matrix polarimeters and and in
particular selecting the retardances and orientation angles of polarization components to …

Calibration and data extraction in nonoptimized Mueller matrix polarimeters

O Rodríguez-Nuñez, JM López-Téllez… - Applied Optics, 2017 - opg.optica.org
We present a method for calibration and data extraction for a nonoptimized Mueller matrix
polarimeter. The advantage of this type of method is a reduction in measurement time for …

Error analysis and compensation for a discrete dual rotating retarder Mueller matrix polarimeter

E Chironi, C Iemmi - Applied optics, 2020 - opg.optica.org
In this work, the error sources that affect a dual rotating retarder polarimeter working in a
discrete rotation scheme are studied. Moreover, those errors not sufficiently analyzed in the …