Causal and fault trees analysis of proton exchange membrane fuel cell degradation

K Brik, F Ben Ammar, A Djerdir… - Journal of Fuel …, 2015 - asmedigitalcollection.asme.org
This paper presents a reliability approach to analyze the degradation of proton exchange
membrane fuel cell. This approach is based on the dependability analysis tools such as the …

A signal-based method for fast PEMFC diagnosis

E Pahon, NY Steiner, S Jemei, D Hissel, P Moçoteguy - Applied Energy, 2016 - Elsevier
This paper deals with a novel signal-based method for fault diagnosis of a proton exchange
membrane fuel cell (PEMFC). Thanks to an in-lab test bench used for the experimental tests …

Fault detection and isolation of PEM fuel cell system based on nonlinear analytical redundancy: An application via parity space approach

A Aitouche, Q Yang, BO Bouamama - The European Physical …, 2011 - cambridge.org
This paper presents a procedure dealing with the issue of fault detection and isolation (FDI)
using nonlinear analytical redundancy (NLAR) technique applied in a proton exchange …

Model-based aging tolerant control with power loss prediction of Proton Exchange Membrane Fuel Cell

M Bressel, M Hilairet, D Hissel… - International Journal of …, 2020 - Elsevier
Abstract Proton Exchange Membrane Fuel Cells are promising energy converters that allow
powering vehicles or buildings in a clean manner. Nevertheless, their performance are …

Robust LPV model-based sensor fault diagnosis and estimation for a PEM fuel cell system

S De Lira, V Puig, J Quevedo - 2010 Conference on Control …, 2010 - ieeexplore.ieee.org
In this paper, a model-based fault diagnosis methodology for PEM fuel cell systems is
presented. The methodology is based on computing residuals using a LPV observer. The …

Fixed time adaptive fault tolerant sliding mode control of PEMFC air supply system

Z Wang, X Guo, Z Dong, N Fan, S Cao - International Journal of Hydrogen …, 2024 - Elsevier
Guaranteeing rapid management of oxygen excess ratio (OER) for proton exchange
membrane fuel cells (PEMFC) under load variations is a challenge with practical …

Model-based data driven approach for fault identification in proton exchange membrane fuel cell

KVS Bharath, F Blaabjerg, A Haque, MA Khan - Energies, 2020 - mdpi.com
This paper develops a model-based data driven algorithm for fault classification in proton
exchange membrane fuel cells (PEMFCs). The proposed approach overcomes the …

PEM fuel cell fault detection and identification using differential method: simulation and experimental validation

E Frappé, A De Bernardinis, O Bethoux… - The European …, 2011 - cambridge.org
PEM fuel cell performance and lifetime strongly depend on the polymer membrane and MEA
hydration. As the internal moisture is very sensitive to the operating conditions (temperature …

Fault tree analysis aimed to design and implement on-field fault detection and isolation schemes for SOFC systems

I Arsie, A Di Filippi, D Marra… - … on Fuel Cell …, 2010 - asmedigitalcollection.asme.org
The paper focuses on a methodological study oriented towards the development of
diagnostic tools for on-field operating solid oxide fuel cell (SOFC) systems. This work is …

Fault diagnosis for fuel cell systems: A data-driven approach using high-precise voltage sensors

Z Li, R Outbib, S Giurgea, D Hissel, A Giraud… - Renewable Energy, 2019 - Elsevier
Reliability and durability are two key hurdles that prevent the widespread use of fuel cell
technology. Fault diagnosis, especially online fault diagnosis, has been considered as one …