Inelastic damage-involved response of colliding buildings during earthquakes

S Mahmoud, R Jankowski - Key Engineering Materials, 2010 - Trans Tech Publ
Interactions between adjacent, insufficiently separated buildings have been repeatedly
observed during major earthquakes. This phenomenon, known as the earthquake-induced …

Pounding between inelastic three-storey buildings under seismic excitations

R Jankowski - Key Engineering Materials, 2016 - Trans Tech Publ
Structural interactions between adjacent, insufficiently separated buildings have been
repeatedly observed during damaging ground motions. This phenomenon, known as the …

Earthquake-induced pounding between equal height buildings with substantially different dynamic properties

R Jankowski - Engineering structures, 2008 - Elsevier
Earthquake-induced structural pounding may result in considerable damage or even
collapse of colliding structures during severe ground motions. The aim of the paper is to …

[PDF][PDF] Non-linear modelling of earthquake induced pounding of buildings

R Jankowski - Earthquake Engineering Structural Dynamics, 2004 - fluid.ippt.gov.pl
The aim of the present paper is to analyse earthquake induced pounding between two
insufficiently separated buildings with different dynamic characteristics. In the analysis …

Analysis of building pounding due to earthquake

SA Anagnostopoulos… - Structural Dynamics-Vol 1, 2022 - taylorfrancis.com
The pounding between adjacent buildings in city blocks due to earthquakes is investigated
through numerical simulations. The buildings are idealized as a series of lumped mass …

Numerical study on pounding between two adjacent buildings under earthquake excitation

H Naderpour, RC Barros, SM Khatami… - Shock and …, 2016 - Wiley Online Library
Seismic excitation, which results in large horizontal relative displacements, may cause
collisions between two adjacent structures due to insufficient separation distance between …

Non‐linear viscoelastic modelling of earthquake‐induced structural pounding

R Jankowski - Earthquake engineering & structural dynamics, 2005 - Wiley Online Library
Past severe earthquakes indicate that structural pounding may cause considerable damage
or even lead to collapse of colliding structures if the separation distance between them is not …

Earthquake-induced pounding between asymmetric steel buildings

B Sołtysik, R Jankowski - Seismic Behaviour and Design of Irregular and …, 2016 - Springer
Earthquake-induced pounding between buildings has been the subject of numerous
numerical and experimental studies in the resent years. The phenomenon may cause …

Investigation on damage-involved structural response of colliding steel structures during ground motions

B Sołtysik, T Falborski, R Jankowski - Key Engineering Materials, 2016 - Trans Tech Publ
Earthquakes are the most unpredictable damaging loads which can affect civil engineering
structures. Due to insufficient separation distance between adjacent structures with different …

[PDF][PDF] Numerical investigation of pounding effects between adjacent buildings

B CHIKH, R Bilal, H BECHTOULA… - 15th European …, 2014 - academia.edu
Post-earthquake damage investigations have illustrated that buildings are exposed to suffer
severe damage or to collapse during moderate to strong ground motion. Among these …