Interreader variability of prostate imaging reporting and data system version 2 in detecting and assessing prostate cancer lesions at prostate MRI

MD Greer, JH Shih, N Lay, T Barrett… - American Journal of …, 2019 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study was to evaluate agreement among radiologists in
detecting and assessing prostate cancer at multiparametric MRI using Prostate Imaging …

Interreader variability in prostate MRI reporting using Prostate Imaging Reporting and Data System version 2.1

G Brembilla, P Dell'Oglio, A Stabile, A Damascelli… - European …, 2020 - Springer
Objectives To evaluate the agreement among readers with different expertise in detecting
suspicious lesions at prostate multiparametric MRI using Prostate Imaging Reporting and …

Accuracy and interobserver agreement for prostate imaging reporting and data system, version 2, for the characterization of lesions identified on multiparametric MRI …

AS Purysko, LK Bittencourt, JA Bullen… - American Journal of …, 2017 - Am Roentgen Ray Soc
OBJECTIVE. The objective of this study was to measure the accuracy and interobserver
agreement of the Prostate Imaging Reporting and Data System, version 2 (PI-RADSv2), for …

Interobserver reproducibility of the PI-RADS version 2 lexicon: a multicenter study of six experienced prostate radiologists

AB Rosenkrantz, LA Ginocchio, D Cornfeld… - Radiology, 2016 - pubs.rsna.org
Purpose To determine the interobserver reproducibility of the Prostate Imaging Reporting
and Data System (PI-RADS) version 2 lexicon. Materials and Methods This retrospective …

Interreader agreement of PI‐RADS v. 2 in assessing prostate cancer with multiparametric MRI: A study using whole‐mount histology as the standard of reference

R Girometti, G Giannarini, F Greco… - Journal of Magnetic …, 2019 - Wiley Online Library
Background Most studies assessing interreader agreement of Prostate Imaging Reporting
and Data System v. 2 (PI‐RADS v2) have used biopsy as the standard of reference, thus …

Standardized reporting of prostate MRI: comparison of the prostate imaging reporting and data system (PI-RADS) version 1 and version 2

S Tewes, N Mokov, D Hartung, V Schick, I Peters… - PloS one, 2016 - journals.plos.org
Introduction Objective of our study was to determine the agreement between version 1 (v1)
and v2 of the Prostate Imaging Reporting and Data System (PI-RADS) for evaluation of …

Interreader agreement with prostate imaging reporting and data system version 2 for prostate cancer detection: a systematic review and meta-analysis

KJ Park, SH Choi, JS Lee, JK Kim, M Kim - The Journal of urology, 2020 - auajournals.org
Purpose: We evaluated interreader agreement with PI-RADS®(Prostate Imaging Reporting
and Data System) version 2 for detection of prostate cancer. Materials and Methods: We …

Assessment of PI-RADS v2 for the detection of prostate cancer

M Kasel-Seibert, T Lehmann, R Aschenbach… - European journal of …, 2016 - Elsevier
Purpose To evaluate the diagnostic performance and inter-reader reliability of the
multiparametric magnetic resonance imaging (mpMRI) based prostate imaging reporting …

Prostate cancer: interobserver agreement and accuracy with the revised prostate imaging reporting and data system at multiparametric MR imaging

BG Muller, JH Shih, S Sankineni, J Marko… - Radiology, 2015 - pubs.rsna.org
Purpose To evaluate accuracy and interobserver variability with the use of the Prostate
Imaging Reporting and Data System (PI-RADS) version 2.0 for detection of prostate cancer …

Variability of the positive predictive value of PI-RADS for prostate MRI across 26 centers: experience of the society of abdominal radiology prostate cancer disease …

AC Westphalen, CE McCulloch, JM Anaokar, S Arora… - Radiology, 2020 - pubs.rsna.org
Background Prostate MRI is used widely in clinical care for guiding tissue sampling, active
surveillance, and staging. The Prostate Imaging Reporting and Data System (PI-RADS) …