Design, implementation, and medical applications of 2-D ultrasound sparse arrays

A Ramalli, E Boni, E Roux, H Liebgott… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
An ultrasound sparse array consists of a sparse distribution of elements over a 2-D aperture.
Such an array is typically characterized by a limited number of elements, which in most …

Sparse 2-D arrays for 3-D phased array imaging-experimental validation

A Austeng, S Holm - IEEE transactions on ultrasonics …, 2002 - ieeexplore.ieee.org
To be able to describe more precisely the behavior of a real-time 3-D ultrasound system with
either a dense array or various sparse designs, experimental data from a 2-D fully …

Application of different spatial sampling patterns for sparse array transducer design

SI Nikolov, JA Jensen - Ultrasonics, 2000 - Elsevier
In the last few years, the efforts of many researchers have been focused on developing 3D
real-time scanners. The use of 2D phased-array transducers makes it possible to steer the …

Wideband 2-D array design optimization with fabrication constraints for 3-D US imaging

E Roux, A Ramalli, H Liebgott… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Ultrasound (US) 2-D arrays are of increasing interest due to their electronic steering
capability to investigate 3-D regions without requiring any probe movement. These arrays …

Density-tapered spiral arrays for ultrasound 3-D imaging

A Ramalli, E Boni, AS Savoia… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
The current high interest in 3-D ultrasound imaging is pushing the development of 2-D
probes with a challenging number of active elements. The most popular approach to limit …

Experimental 3-D ultrasound imaging with 2-D sparse arrays using focused and diverging waves

E Roux, F Varray, L Petrusca, C Cachard, P Tortoli… - Scientific reports, 2018 - nature.com
Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are
increasingly investigated. However, the experimental test of new 3-D US approaches is …

Properties of the beampattern of weight-and layout-optimized sparse arrays

S Holm, B Elgetun, G Dahl - IEEE Transactions on Ultrasonics …, 1997 - ieeexplore.ieee.org
Theory for random arrays predicts a mean sidelobe level given by the inverse of the number
of elements. In practice, however, the sidelobe level fluctuates much around this mean. In …

Design of optimal 2-D nongrid sparse arrays for medical ultrasound

B Diarra, M Robini, P Tortoli… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
Three-dimensional imaging with 2-D matrix probes is one of the most exciting recent
ultrasound innovations. Unfortunately, the number of elements of a 2-D matrix probe is often …

Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays

SS Brunke, GR Lockwood - IEEE transactions on ultrasonics …, 1997 - ieeexplore.ieee.org
The fabrication of a dense (one-half wavelength element spacing) two-dimensional (2D)
transducer array suitable for medical ultrasound imaging is unrealistic using existing …

Design of sparse array imaging systems

GR Lockwood, FS Foster - 1995 IEEE ultrasonics symposium …, 1995 - ieeexplore.ieee.org
A method for designing sparse periodic arrays is described. Grating lobes in the two-way
radiation pattern are avoided by using different element spacings for transmission and …