[PDF][PDF] The structural performance of axially loaded CFST columns under various loading conditions

F Huang, X Yu, B Chen - Steel & Composite Structures, 2012 - researchgate.net
Concrete filled steel tube (CFST) structures have been used widely in high-rise buildings
and bridges due to the efficiency of structurally favourable interaction between the steel tube …

An analysis-based model for axially loaded circular CFST columns

MH Lai, JCM Ho - Thin-Walled Structures, 2017 - Elsevier
Abstract Concrete-filled-steel-tube (CFST) columns have been increasingly adopted in many
modern structures due to the beneficial composite action between steel tube and core …

Unified theoretical model for axially loaded concrete-filled steel tube stub columns with different cross-sectional shapes

S Lin, YG Zhao, ZH Lu, XF Yan - Journal of Structural Engineering, 2021 - ascelibrary.org
The existing theoretical models for the analysis of concrete-filled steel tube (CFST) columns
are mainly limited to circular specimens. This paper is aimed at developing a unified …

Behaviour and design of high strength CFST columns with slender sections

TT Nguyen, HT Thai, T Ngo, B Uy, D Li - Journal of Constructional Steel …, 2021 - Elsevier
The behaviour of high strength concrete-filled steel tube (CFST) columns with slender
sections under concentric loading is experimentally explored in this study. The test program …

Experimental research on load separation of concrete-filled circular steel tube short columns

P Qin, X Li, W Yi - Journal of Constructional Steel Research, 2024 - Elsevier
In recent years, scholars from various countries have conducted extensive experiments and
analytical studies on the axial compressive behavior of circular concrete-filled steel tube …

The effects of cross-sectional shapes on the axial performance of concrete-filled steel tube columns

P Ayough, Z Ibrahim, NHR Sulong, PC Hsiao - Journal of Constructional …, 2021 - Elsevier
Concrete-filled steel tubular (CFST) columns have been used in the construction of modern
structures such as high-rise buildings and bridges as well as infrastructures as they provide …

[HTML][HTML] Practical design equations of the axial compressive capacity of circular CFST stub columns based on finite element model analysis incorporating constitutive …

F Ding, Z Cao, F Lyu, S Huang, M Hu, Q Lin - Case Studies in Construction …, 2022 - Elsevier
Step into the 21st century, high strength materials have been increasingly used in
engineering practice. However, current design codes for concrete-filled steel tube (CFST) …

Finite element analysis of CFT columns subjected to an axial compressive force and bending moment in combination

HT Hu, CS Huang, ZL Chen - Journal of Constructional Steel Research, 2005 - Elsevier
Proper material constitutive models for concrete-filled tube (CFT) columns subjected to an
axial compressive force and bending moment in combination are proposed and verified in …

A theoretical axial stress-strain model for circular concrete-filled-steel-tube columns

MH Lai, JCM Ho - Engineering Structures, 2016 - Elsevier
Abstract Concrete-filled-steel-tube (CFST) columns are widely adopted in many structures
nowadays attributed to the superior behaviour developed by the composite action. However …

Composite action of hexagonal concrete-filled steel tubular stub columns under axial loading

F Ding, Z Li, S Cheng, Z Yu - Thin-Walled Structures, 2016 - Elsevier
Four groups of axial compression tests on hexagonal CFT stub columns have been carried