[PDF][PDF] Impulse flashover voltages in air at low pressure

O Kalenderli, E Onal, A Merev, K Mardikyan - … International symposium on …, 2003 - itu.edu.tr
In this study, impulse flashover experiment results on insulator specimens with different
profiles in a uniform electric field in air at low pressure are presented. Under positive and …

Profile effect on surface flashover in a uniform field

NL Allen, PN Mikropoulos - 1999 Eleventh International …, 1999 - ieeexplore.ieee.org
Flashover results on insulator specimens with different profiles in a uniform electric field in
air are presented. Under direct voltages, positive streamers, propagating along cylindrical …

Surface discharge processes of solid insulator under negative impulse voltage in atmospheric air

T Shimazaki - [1991] Proceedings of the 3rd International …, 1991 - ieeexplore.ieee.org
The breakdown phenomena on the surface of a acrylic plates, 1 to 10 mm thick, were
investigated under negative impulse voltage in atmospheric air. The 50% flashover voltage …

Micro-discharge and surface flashover of insulators in vacuum

L Ding, CR Li, J Wang… - 1999 Annual Report …, 1999 - ieeexplore.ieee.org
Recently surface flashover phenomena of insulators in vacuum were investigated with an
impulse voltage (0.7/4/spl mu/s). The test samples studied were 99.9% alumina specimens …

Flashover processes on the surface of solid insulators under positive impulse voltage in the atmosphere

T Shimazaki, I Tsuneyasu - IEEE transactions on electrical …, 1990 - ieeexplore.ieee.org
The surface discharge phenomena on 1-10 mm-thick acrylic plates were investigated under
positive impulse voltage in air at atmospheric pressure. The corona inception voltages and …

Flashover along cylindrical insulating surfaces in a nonuniform field under positive switching impulse voltages

LA Lazaridis, PN Mikropoulos - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
Results are presented concerning discharge development and breakdown in air and along
cylindrical insulating surfaces in a 12 cm long rod-plane gap under positive switching …

Flashover characteristics of impulse voltages on solid dielectric surfaces under high humidity

S Hasegawa, H Akagami - Japanese journal of applied physics, 1990 - iopscience.iop.org
For the design of electrical insulating devices, it is very important to observe discharge
phenomena on the needle-to-plate electrode gap under high humidity. In this study, impulse …

Impulse flashover of air-gaps and insulators in the voltage range 1–2.5 MV

WG Standring, DN Browning, RC Hughes… - Proceedings of the …, 1963 - IET
Impulse flashover voltages are given for air-gaps, string insulators and post insulators which
might be used in transmission systems at voltages from 132 to 400 kV. For a given length of …

Flashover characteristics and surface processes under negative impulse voltage in atmospheric air

T Shimazaki - IEEE transactions on electrical insulation, 1992 - ieeexplore.ieee.org
Breakdown phenomena on surfaces of acrylic plates, 1 to 10 mm thick, were investigated
under negative impulse voltage in atmospheric air. The 50% flashover voltage V/sub 50/and …

Experimental investigation of surface charge distribution on insulator in vacuum under impulse voltage

L Ding, CR Li, J Wang, Z Wang, X Chi… - Conference Record of …, 2000 - ieeexplore.ieee.org
In this study, the surface charge distribution on insulators in vacuum has been investigated
under an impulse voltage (0.7/4/spl mu/s) with a non-uniform field electrode system. The …