Short circuit fault tolerant system for Matrix Converter

V Tran - 2016 - IET
The paper proposes a short circuit fault tolerant system for the conventional Matrix Converter
(MC) to increase the immune capability of the MC against short circuit fault. In this paper, the …

Open-switch fault diagnosis and fault tolerant for matrix converter with finite control set-model predictive control

T Peng, H Dan, J Yang, H Deng, Q Zhu… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
To improve the reliability of the matrix converter (MC), a fault diagnosis method to identify a
single open-switch fault is proposed in this paper. The introduced fault diagnosis method is …

Fault tolerant strategy for inverter stage in indirect matrix converter

QH Tran, TW Chun, HH Lee - IECON 2013-39th Annual …, 2013 - ieeexplore.ieee.org
This paper proposes an open circuit fault tolerant strategy with a fault detector for the inverter
stage in indirect matrix converter (IMC). When an open switch fault occurs in IMC, the …

An on-line fault detection and a post-fault strategy to improve the reliability of matrix converters

JD Dasika, M Saeedifard - 2013 Twenty-Eighth Annual IEEE …, 2013 - ieeexplore.ieee.org
This paper proposes a new on-line fault detection method to detect open-switch faults in a
Matrix Converter (MC). The proposed fault detection method is based on a two-step …

Design of Advanced Fault-Tolerant Control System for Three-Phase Matrix Converter Using Artificial Neural Networks

F Ahmad, T Alsuwian, AA Amin, M Adnan… - IEEE Access, 2023 - ieeexplore.ieee.org
The Matrix converters (MCs) are widely used in a large number of applications such as
Aircraft, Submarines, and AC drives. In these applications, because of the many chances of …

Error-voltage-based open-switch fault diagnosis strategy for matrix converters with model predictive control method

H Dan, T Peng, M Su, H Deng, Q Zhu… - IEEE Transactions …, 2017 - ieeexplore.ieee.org
This paper proposes an error-voltage-based open-switch fault-diagnosis a strategy for a
matrix converter (MC). A finite control set model predictive control method is used to operate …

A post-fault modulation strategy to control the matrix converter under an open-switch failure

JD Dasika, M Saeedifard - 2014 IEEE Applied Power …, 2014 - ieeexplore.ieee.org
In this paper, a new post-fault modulation strategy is proposed to operate the direct matrix
converter (MC) as close as possible to its desired normal operating under an open-switch …

Simple fault diagnosis and fault-tolerant strategy based on model predictive control for matrix converter

E Lee, KB Lee, YD Yoon - 2014 IEEE 23rd International …, 2014 - ieeexplore.ieee.org
This paper presents a simple fault detection method and fault-tolerant strategy based on the
model predictive control theory. The proposed fault detection method can detect and locate …

An open circuit fault-tolerant control strategy for matrix convertor based on mathematical construction modulation

D Hui, P Tao, D Hanbing, H Hua - The 27th Chinese Control …, 2015 - ieeexplore.ieee.org
Matrix convertor is a direct AC/AC converter with many advantages. However, it could
heavily impact the operation performance and the use of life when having open circuit fault …

Matrix converter open circuit behavior analysis

J Zhang, C Brunson, J Bowden… - IECON 2016-42nd …, 2016 - ieeexplore.ieee.org
The matrix converter current recirculating path during an open circuit condition is given in
detail with the aim of contributing more expert knowledge to a fault detection system for …