Moisture estimation in power transformer oil using acoustic signals and spectral kurtosis

VCMN Leite, GFC Veloso, LEB da Silva… - Measurement …, 2016 - iopscience.iop.org
The aim of this paper is to present a new technique for estimating the contamination by
moisture in power transformer insulating oil based on the spectral kurtosis analysis of the …

Using partial discharge as sample signal source to identify contamination moisture pattern in power transformer insulating oil

GFC Veloso, LEB da Silva, I Noronha… - IECON 2010-36th …, 2010 - ieeexplore.ieee.org
The properly behavior of power transformers is highly dependent of the insulation health.
So, the insulation condition assessment can provide information to a system of diagnosis …

Influence of moisture and temperature on the frequency domain spectroscopy characteristics of transformer oil

L Liu, H Wu, T Liu, H Feng, H Tian… - 2016 IEEE International …, 2016 - ieeexplore.ieee.org
Transformer oil is an important liquid dielectric of oil-immersed transformers. Moisture and
temperature bring a great harm on the transformer insulation. This research was carried out …

Investigation of water content in power transformer oils through ultrasonic measurements

TTC Palitó, YAO Assagra, RAC Altafim… - … IEEE Conference on …, 2018 - ieeexplore.ieee.org
Transformers are one of the most important equipment found in electrical power systems.
Thus, their status must be constantly monitored to avoid critical failures. The analysis of the …

[PDF][PDF] Analysis of insulating parameters of oil transformer by time and frequency methods

M Gutten, M Kucera, P Brncal, M Sebok… - Diagnostyka, 2020 - bibliotekanauki.pl
In the paper is presented experimental analysis and diagnostics of insulating system oil-
paper for power transformers. In the first part of the paper is described base theory about …

Estimation of water content in a power transformer using moisture dynamic measurement of its oil

V Sarfi, S Mohajeryami, A Majzoobi - High Voltage, 2017 - Wiley Online Library
Careful monitoring of high voltage equipments and diagnosing the critical conditions before
they lead to a disaster are prerequisites of condition‐based maintenance. Moisture content …

Acoustic energy shifting in transformer oil at different temperatures

X Wang, B Li, Z Xiao, OL Russo… - IEEE transactions on …, 2005 - ieeexplore.ieee.org
In this letter, partial discharge (PD) acoustic waves for different temperatures have been
detected using a piezoelectric acoustic sensor. The experiments results are analyzed using …

Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of moisture content in paper–oil insulation system

R Liao, J Liu, L Yang, J Gao, Y Zhang… - IET Electric Power …, 2015 - Wiley Online Library
The ageing rate of cellulose insulation materials (paper/pressboard) in oil‐impregnated
transformers is largely determined by moisture. In this paper, several experiments were …

[HTML][HTML] Detection and analysis of partial discharges in oil-immersed power transformers using low-cost acoustic sensors

H Besharatifard, S Hasanzadeh… - Applied Sciences, 2022 - mdpi.com
Partial Discharge (PD) is one of the symptoms of an electrical insulation problem, and its
permanence can lead to the complete deterioration of the electrical insulation in high …

[PDF][PDF] Thermo-acoustic water analyzer in hydrocarbon emulsions with Kalman filter

MA Al-Khedher, TM Younes, MAK Alia - American Journal of Applied …, 2012 - Citeseer
Problem statement: Water detection in hydrocarbon emulsions represents a serious
challenge in petroleum production industry. The elemenation of measurment noises is also …