A kerfless dual-layer transducer combined with beamforming by spatial matched filtering for high frame rate ultrasound imaging

Y Chen, JT Yen - 2014 IEEE International Ultrasonics …, 2014 - ieeexplore.ieee.org
Dicing is typically required to create elements for array transducers made with piezoelectric
ceramics. Kerfs, which are the cutting spaces generated during dicing, are introduced to …

High frequency piezo-composite transducer array designed for ultrasound scanning applications

A Nguyen-Dinh, L Ratsimandresy… - 1996 IEEE …, 1996 - ieeexplore.ieee.org
A 20 MHz high density linear array transducer is presented in this paper, This array has
been developed using an optimized ceramic-polymer composite material. The electro …

Coherent multi-transducer ultrasound imaging through aberrating media

L Peralta, M Reinwald, JV Hajnal… - 2019 IEEE …, 2019 - ieeexplore.ieee.org
Transducers with larger aperture size are desirable in ultrasound imaging to improve
resolution and image quality. However, in practice inhomogeneities and aberrating layers …

1–3 piezocomposite design optimised for high frequency kerfless transducer arrays

CEM Demore, S Cochran… - 2009 IEEE …, 2009 - ieeexplore.ieee.org
Piezocomposites that can operate at frequencies above 30 MHz without spurious modes are
required in order to develop sufficiently sensitive high frequency arrays for high resolution …

Crosstalk optimization of 5 MHz linear array transducer based on PZT/epoxy piezoelectric composite

D Cheng, J Li, Q Yue, R Liang, X Dong - Sensors and Actuators A: Physical, 2022 - Elsevier
Array ultrasonic transducers using electronic scanning method can obtain high frame rate
and high-accuracy images compared with single-element transducers. However, for array …

Investigation of kerfless PZT and PVDF based ultrasound arrays

D Ackermann, G Schmitz - Biomedical Engineering/Biomedizinische …, 2012 - degruyter.com
Abstract For high frequency (> 20 MHz) ultrasound transducer arrays, structures in the range
of a few micrometers are required. Especially, separating transducer elements of a few …

Impact of aperture, depth, and acoustic clutter on the performance of coherent multi-transducer ultrasound imaging

L Peralta, A Ramalli, M Reinwald, RJ Eckersley… - Applied Sciences, 2020 - mdpi.com
Transducers with a larger aperture size are desirable in ultrasound imaging to improve
resolution and image quality. A coherent multi-transducer ultrasound imaging system …

A novel approach for reducing Multi Line Transmission cross-talks using 2D transducer arrays

B Denarie, H Torp, T Bjåstad - 2012 IEEE International …, 2012 - ieeexplore.ieee.org
Multi-Line Transmission (MLT) is a potential approach to increase the framerate in 3D
echocardiography, but suffers from artifacts caused by the cross-talk between the …

A casting-based fabrication process for a high-frequency piezo-electric linear array

GJ van Dijk, EJ Alles… - 2012 IEEE International …, 2012 - ieeexplore.ieee.org
Novel ultrasound arrays used in medical imaging contain many small elements (down to
100 μm) operating at high frequencies (upto tens of MHz). In such arrays, each element …

Injection molded fine-scale piezoelectric composite transducers

LJ Bowen, RL Gentilman, HT Pham… - 1993 Proceedings …, 1993 - ieeexplore.ieee.org
A ceramic injection molding process has been developed for net-shape forming complex-
shaped PZT 1-3 and 2-2 element arrays that are suitable for direct assembly into composite …