On the impacts of ageing and moisture on dielectric response of oil impregnated paper insulation systems

A Betie, F Meghnefi, I Fofana… - 2012 Annual Report …, 2012 - ieeexplore.ieee.org
In this contribution, dielectric measurements in the frequency domain spectroscopy (FDS)
were undertaken on oil impregnated paper samples in order to assess, with accuracy, the …

Low temperature and moisture effects on oil-paper insulation dielectric response in frequency domain

I Fofana, H Hemmatjou, F Meghnefi… - 2009 IEEE Electrical …, 2009 - ieeexplore.ieee.org
Results of Frequency Domain Spectroscopy measurements are known to be largely
influenced by environmental conditions, such as the temperature. From fields and laboratory …

Dielectric response of mineral oil impregnated cellulose and the impact of aging

D Linhjell, L Lundgaard… - IEEE Transactions on …, 2007 - ieeexplore.ieee.org
Dielectric response is a non-invasive diagnostic method with a potential to give information
about the status of the solid insulation in a power transformer. To investigate what conditions …

Assessing oil paper insulation conditions by poles computed from Frequency Domain Spectroscopy

Y Hadjadj, I Fofana, F Meghnefi… - 2011 IEEE international …, 2011 - ieeexplore.ieee.org
In this contribution, the dielectric dissipation factor of oil impregnated paper were monitored
along with the degree of polymerization. A series of experiments have been performed …

Neural network approach to separate aging and moisture from the dielectric response of oil impregnated paper insulation

A Bétié, F Meghnefi, I Fofana, Z Yéo… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
This paper presents a study of the impact of two important parameters, moisture and aging of
the oil/paper dielectric used as insulation in power transformers. The way in which these two …

On the feasibility of using poles computed from frequency domain spectroscopy to assess oil impregnated paper insulation conditions

Y Hadjadj, F Meghnefi, I Fofana, H Ezzaidi - Energies, 2013 - mdpi.com
Frequency Domain Spectroscopy (FDS) is an effective tool allowing assessing the condition
of oil-paper insulation system in power equipment. However, results from these …

Detection of oil-pressboard insulation aging with dielectric spectroscopy in time and frequency domain measurements

O Hassan, AA Shyegani, H Borsi… - Proceedings of the …, 2004 - ieeexplore.ieee.org
The insulation system of power transformers consists of oil and cellulose, whose dielectric
properties are strongly influenced by moisture, temperature and aging. Their condition can …

Effects of moisture and temperature on the frequency domain spectroscopy analysis of power transformer insulation

JH Yew, MK Pradhan, TK Saha - … of Electrical Energy in the 21st …, 2008 - ieeexplore.ieee.org
Dielectric testing techniques such as frequency domain spectroscopy (FDS) is currently
being widely used by the power utilities for the assessment of the condition of transformer oil …

Investigating the impacts of temperature on the dielectric response of oil-paper insulation system

H Peng, M Dong, M Ren, J Wei… - Proceedings of 2011 …, 2011 - ieeexplore.ieee.org
In recent decades, Dielectric Response Technique is widely used by power utilities for
assessment of the condition of electrical equipments as a non-destructive dielectric testing …

A new method for assessment condition of oil-paper insulation based on the characteristics of frequency domain spectroscopy

Y Liu, T Zhang, X Zhang - 2016 IEEE International Conference …, 2016 - ieeexplore.ieee.org
The Frequency Domain spectroscopy is a nondestructive electric diagnosis. It's very suitable
for transformer oil-paper insulation condition of field detection, the actual development of the …