DC-link capacitor voltage regulation for three-phase three-level inverter-based shunt active power filter with inverted error deviation control

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2016 - mdpi.com
A new control technique known as inverted error deviation (IED) control is incorporated into
the main DC-link capacitor voltage regulation algorithm of a three-level neutral-point diode …

Three-level inverter-based shunt active power filter in three-phase three-wire and four-wire systems

O Vodyakho, CC Mi - IEEE transactions on power electronics, 2009 - ieeexplore.ieee.org
This paper presents a direct current-space-vector control of an active power filter (APF)
based on a three-level neutral-point-clamped (NPC) voltage-source inverter. The proposed …

Novel direct current-space-vector controlfor shunt active power filters basedon the three-level inverter

O Vodyakho, D Hackstein, A Steimel… - IEEE transactions on …, 2008 - ieeexplore.ieee.org
The growing number of electric drives with non-sinusoidal line currents has given increased
interest in active power filters (APF), to avoid grid problems caused by harmonic distortions …

A dual-function instantaneous power theory for operation of three-level neutral-point-clamped inverter-based shunt active power filter

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2018 - mdpi.com
This paper proposes a simple yet effective reference current generation algorithm based on
instantaneous power pq theory to enhance mitigation performance of a three-phase three …

Hybrid direct power/current control using feedback linearization of three-level four-leg voltage source shunt active power filter

M Bouzidi, A Benaissa, S Barkat - International journal of electrical power & …, 2014 - Elsevier
This paper proposes a hybrid direct power/current control-three dimensional space vector
modulation combined with feedback linearization control for three-phase three-level four-leg …

A self-tuning filter-based adaptive linear neuron approach for operation of three-level inverter-based shunt active power filters under non-ideal source voltage …

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2017 - mdpi.com
This paper presents a self-tuning filter (STF)-based adaptive linear neuron (ADALINE)
reference current generation algorithm to enhance the operation of a three-phase three …

Neutral‐point voltage deviation control for three‐level inverter‐based shunt active power filter with fuzzy‐based dwell time allocation

Y Hoon, MAM Radzi, MK Hassan… - IET Power …, 2017 - Wiley Online Library
Three‐level inverters have emerged as the main alternative to replace the use of standard
two‐level inverters in current harmonics mitigation. Neutral‐point diode clamped (NPC) …

A refined self-tuning filter-based instantaneous power theory algorithm for indirect current controlled three-level inverter-based shunt active power filters under non …

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2017 - mdpi.com
In this paper, a refined reference current generation algorithm based on instantaneous
power (pq) theory is proposed, for operation of an indirect current controlled (ICC) three …

Performance analysis of ANN based three-phase four-wire shunt active power filter for harmonic mitigation under distorted supply voltage conditions

S Agrawal, DK Palwalia, M Kumar - IETE Journal of Research, 2022 - Taylor & Francis
This paper presents the design and implementation of three-phase four-wire shunt active
power filter (SAPF). It consists of insulated gate bipolar transistors, IGBT based current …

[PDF][PDF] A simplified synchronous reference frame for indirect current controlled three-level inverter-based shunt active power filters

Y Hoon, MAM Radzi, MK Hassan… - Journal of Power …, 2016 - koreascience.kr
This paper presents a new simplified harmonics extraction algorithm based on the
synchronous reference frame (SRF) for an indirect current controlled (ICC) three-level …