Estimation of spatial-temporal gait parameters in level walking based on a single accelerometer: Validation on normal subjects by standard gait analysis

F Bugané, MG Benedetti, G Casadio, S Attala… - Computer methods and …, 2012 - Elsevier
This paper investigates the ability of a single wireless inertial sensing device stuck on the
lower trunk to provide spatial-temporal parameters during level walking. The 3-axial …

Assessment of walking features from foot inertial sensing

AM Sabatini, C Martelloni, S Scapellato… - IEEE Transactions on …, 2005 - ieeexplore.ieee.org
An ambulatory monitoring system is developed for the estimation of spatio-temporal gait
parameters. The inertial measurement unit embedded in the system is composed of one …

Estimation of stride length in level walking using an inertial measurement unit attached to the foot: A validation of the zero velocity assumption during stance

A Peruzzi, U Della Croce, A Cereatti - Journal of Biomechanics, 2011 - Elsevier
In a variety of applications, inertial sensors are used to estimate spatial parameters by
double integrating over time their coordinate acceleration components. In human movement …

Inertial measurement unit-based estimation of foot trajectory for clinical gait analysis

K Hori, Y Mao, Y Ono, H Ora, Y Hirobe… - Frontiers in …, 2020 - frontiersin.org
Gait analysis is used widely in clinical practice to evaluate abnormal gait caused by disease.
Conventionally, medical professionals use motion capture systems or make visual …

Towards mobile gait analysis: concurrent validity and test-retest reliability of an inertial measurement system for the assessment of spatio-temporal gait parameters

F Kluge, H Gaßner, J Hannink, C Pasluosta, J Klucken… - Sensors, 2017 - mdpi.com
The purpose of this study was to assess the concurrent validity and test–retest reliability of a
sensor-based gait analysis system. Eleven healthy subjects and four Parkinson's disease …

Wearable accelerometer system for measuring the temporal parameters of gait

JA Lee, SH Cho, JW Lee, KH Lee… - 2007 29th Annual …, 2007 - ieeexplore.ieee.org
A small and wireless accelerometer system was developed for the estimation of temporal
gait parameters. The new system was built using two 3-axis accelerometers. Measurement's …

Data management in gait analysis for clinical applications

MG Benedetti, F Catani, A Leardini, E Pignotti… - Clinical …, 1998 - Elsevier
Objective. To study the reliability of gait analysis data obtained using the Calibrated
Anatomical System Technique (cast) protocol and to verify the suitability and repeatability of …

Mobile inertial sensor based gait analysis: Validity and reliability of spatiotemporal gait characteristics in healthy seniors

L Donath, O Faude, E Lichtenstein, G Pagenstert… - Gait & posture, 2016 - Elsevier
Gait analysis is commonly used to identify gait changes and fall risk in clinical populations
and seniors. Body-worn inertial sensor based gait analyses provide a feasible alternative to …

Concurrent related validity of the GAITRite® walkway system for quantification of the spatial and temporal parameters of gait

B Bilney, M Morris, K Webster - Gait & posture, 2003 - Elsevier
The GAITRite® is a portable gait analysis tool for automated measurement of spatiotemporal
gait parameters. Although frequently used for clinical and research purposes, the concurrent …

Assessment of spatio-temporal parameters during unconstrained walking

W Zijlstra - European journal of applied physiology, 2004 - Springer
This paper presents an analysis of spatio-temporal gait parameters during overground
walking based upon a method that needs only lower trunk accelerations. Twenty-six healthy …