A novel real-time chirp measurement method for ultrashort optical pulses

K Mogi, K Naganuma, H Yamada - Japanese journal of applied …, 1988 - iopscience.iop.org
Rapid measurements of ultrashort optical pulse chirping were realized with a newly
developed real-time chirp monitor. The application of a moving coil translator and electrical …

Sensitive ultrashort pulse chirp measurement

DA Bender, MP Hasselbeck, M Sheik-Bahae - Optics letters, 2006 - opg.optica.org
The chirp of an ultrashort laser pulse can be extracted with high accuracy from a modified
spectrum autointerferometric correlation waveform by using a new time domain algorithm …

Phase-sensitive single-pulse autocorrelator for ultrashort laser pulses

G Szabó, Z Bor, A Müller - Optics letters, 1988 - opg.optica.org
Phase-sensitive single-pulse autocorrelator for ultrashort laser pulses clickable element to
expand a topic LOGIN OR CREATE ACCOUNT PRISM SUBMISSION This website uses …

Measurement of the chirp characteristics of linearly chirped pulses by a frequency domain interference method

W Fan, B Zhu, Y Wu, F Qian, M Shui, S Du, B Zhang… - Optics …, 2013 - opg.optica.org
A linear optical technique for chirp characteristics measurement based on frequency domain
interference is developed. This technique can be applied to measure the temporal structure …

Real-time chirp diagnostic for ultrashort laser pulses

T Hirayama, M Sheik-Bahae - Optics letters, 2002 - opg.optica.org
Real-time chirp diagnostic for ultrashort laser pulses clickable element to expand a topic LOGIN
OR CREATE ACCOUNT PRISM SUBMISSION This website uses cookies to deliver some of …

Direct measurement of chirped optical pulses with picosecond resolution

ASL Gomes, AS Gouveia-Neto, JR Taylor - Electronics Letters, 1986 - infona.pl
Direct measurement of chirped optical pulses with picosecond resolution × Close The
Infona portal uses cookies, ie strings of text saved by a browser on the user's device. The …

General method for ultrashort light pulse chirp measurement

K Naganuma, K Mogi, H Yamada - IEEE Journal of Quantum …, 1989 - ieeexplore.ieee.org
Conditions to retrieve pulse intensity and chirp from autocorrelation signals are
mathematically discussed. The interferometric SHG autocorrelation signal and the …

Control of frequency chirp in nanosecond-pulsed laser spectroscopy. 1. Optical-heterodyne chirp analysis techniques

RT White, Y He, BJ Orr, M Kono, KGH Baldwin - JOSA B, 2004 - opg.optica.org
We evaluate ways to analyze optical-heterodyne measurements of frequency chirp in
pulsed, single-longitudinal-mode output from lasers (or other coherent light sources) that …

Chirped light and its characterization using the cross-correlation technique

KW Delong, J Yumoto - JOSA B, 1992 - opg.optica.org
We analyze the cross-correlation (sum-frequency generation) method of chirp measurement
of short light pulses. We find that there are two complementary methods to measure the …

[引用][C] Wideband chirp measurement technique for high bit rate sources

RA Saunders, JP King, I Hardcastle - Electronics Letters, 1994 - IET
modulation of the SOA gain by the signal beam. Page 1 sation. however, the original eye is
effectively recovered with little distortion after 200 km. When the ratio of the signal to pump …