Optimal sizing of hybrid energy storage systems to mitigate wind power fluctuations

IN Moghaddam, B Chowdhury - 2016 IEEE Power and Energy …, 2016 - ieeexplore.ieee.org
Wind energy penetration level may be adversely impacted by frequency deviations as a
result of wind power fluctuations. Energy Storage System (ESS) can be a viable candidate …

Sizing an energy storage system to minimize wind power imbalances from the hourly average

T Boutsika, S Santoso - 2012 IEEE Power and Energy Society …, 2012 - ieeexplore.ieee.org
Variability and uncertainty in wind power represent significant risks to system operators as
well as wind farm owners. The coupling of wind with energy storage systems has been used …

Probabilistic forecasting based sizing and control of hybrid energy storage for wind power smoothing

C Wan, W Qian, C Zhao, Y Song… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
With the increasing wind power integration, the security and economy of the power system
operations are greatly influenced by the intermittency and fluctuation of wind power. Due to …

A review on wind power smoothing using high-power energy storage systems

PHA Barra, WC de Carvalho, TS Menezes… - … and Sustainable Energy …, 2021 - Elsevier
Wind energy has been widely explored in recent decades and the integration of this
renewable resource is increasing due to many factors, eg, the need to mitigate climate …

Probabilistic approach for power capacity specification of wind energy storage systems

X Wang, M Yue, E Muljadi… - IEEE transactions on …, 2013 - ieeexplore.ieee.org
To accommodate the wind power fluctuations, a hybrid energy storage system (HESS)
consisting of a battery energy storage system (BESS) and a supercapacitor is evaluated in …

Two‐stage optimal MPC for hybrid energy storage operation to enable smooth wind power integration

T Guo, Y Zhu, Y Liu, C Gu, J Liu - IET Renewable Power …, 2020 - Wiley Online Library
The large‐scale penetration of wind generation imposes challenges on the security of power
system operation due to the intermittency and stochastic volatility. Hybrid energy storage …

Wavelet-based capacity configuration and coordinated control of hybrid energy storage system for smoothing out wind power fluctuations

Q Jiang, H Hong - IEEE Transactions on Power Systems, 2012 - ieeexplore.ieee.org
Stochastically fluctuating wind power has a negative impact on power grid operations. This
paper presents a wind power filtering approach to mitigate short-and long-term fluctuations …

A method for optimal sizing hybrid energy storage system for smoothing fluctuations of wind power

M Pang, Y Shi, W Wang, X Yuan - 2016 IEEE PES Asia-Pacific …, 2016 - ieeexplore.ieee.org
A hybrid energy storage system (HESS) is integrated with a wind farm to smooth out its
fluctuations in order to reduce the impact on the grids. This paper presents a cutoff frequency …

Optimal sizing of energy storage considering the spatial‐temporal correlation of wind power forecast errors

C Wang, Q Teng, X Liu, F Zhang, S He… - IET Renewable …, 2019 - Wiley Online Library
Energy storage is considered as an effective approach to deal with the power deviation that
caused by the stochastic wind power forecast error. Because of the spatial‐temporal …

Optimal energy storage sizing and control for wind power applications

TKA Brekken, A Yokochi… - IEEE Transactions …, 2010 - ieeexplore.ieee.org
The variable output of a large wind farm presents many integration challenges, especially at
high levels of penetration. The uncertainty in the output of a large wind plant can be covered …