A new image blood pressure sensor based on PPG, RRT, BPTT, and harmonic balancing

SC Huang, PH Hung, CH Hong… - IEEE sensors …, 2014 - ieeexplore.ieee.org
A new blood pressure (BP) sensor, also named sphygmomanometer, is developed in this
paper for estimating BPs accurately from fingertips. The hardware of the sensor is a low-cost …

Novel blood pressure estimation method using single photoplethysmography feature

Y Chen, S Cheng, T Wang, T Ma - 2017 39th Annual …, 2017 - ieeexplore.ieee.org
Continuous blood pressure (BP) monitoring has a significant meaning to the prevention and
early diagnosis of cardiovascular disease. However, existing continuous BP monitoring …

[HTML][HTML] Blood pressure estimation algorithm based on photoplethysmography pulse analyses

SC Kim, SH Cho - Applied Sciences, 2020 - mdpi.com
Feature Application In this study, we have developed a PPG algorithm for ultra-small blood
pressure meas-urement, proposed an existing air-pressurized product and a method to …

Non-invasive blood pressure estimation using phonocardiogram

AE Dastjerdi, M Kachuee… - 2017 IEEE international …, 2017 - ieeexplore.ieee.org
This paper presents a novel approach based on pulse transit time (PTT) for the estimation of
blood pressure (BP). In order to achieve this goal, a data acquisition hardware is designed …

Symmetrical Photoplethysmogram Signal based Cuff-less Blood Pressure Estimation

Z Liu, L Xiao, Y Liu, L Gao, J Zhang… - IEEE Sensors Journal, 2024 - ieeexplore.ieee.org
Cuff-less blood pressure (BP) is estimated via the pulse wave velocity (PWV) between two
sensors located on the superficial artery of the human body, such as the index fingers …

Cuffless blood pressure estimation using dual physiological signal and its morphological features

LH Wang, KK Sun, CX Xie, MH Fan… - IEEE Sensors …, 2023 - ieeexplore.ieee.org
Prehypertension is difficult to diagnose early because of its hidden nature. Long-term
monitoring of blood pressure (BP) can help in the early detection and timely treatment of this …

Cuff-less blood pressure measurement from dual-channel photoplethysmographic signals via peripheral pulse transit time with singular spectrum analysis

Y Wang, Z Liu, S Ma - Physiological measurement, 2018 - iopscience.iop.org
Objective: This paper proposes an unobtrusive blood pressure (BP) measurement system
design with a motion artifact (MA) compensation strategy as a potential surrogate to the …

Blood pressure measurement from photo-plethysmography to pulse transit time

CZ Myint, KH Lim, KI Wong… - 2014 ieee conference …, 2014 - ieeexplore.ieee.org
Blood Pressure (BP) is one of the vital signs in the clinical assessment of patients in both
acute and chronic care settings. However, existing BP measurement devices are less …

[HTML][HTML] Photoplethysmography-based continuous systolic blood pressure estimation method for low processing power wearable devices

R Gircys, A Liutkevicius, E Kazanavicius… - Applied sciences, 2019 - mdpi.com
Regardless of age, it is always important to detect deviations in long-term blood pressure
from normal levels. Continuous monitoring of blood pressure throughout the day is even …

[HTML][HTML] A new wearable device for blood pressure estimation using photoplethysmogram

R Lazazzera, Y Belhaj, G Carrault - Sensors, 2019 - mdpi.com
We present a novel smartwatch, CareUp®, for estimating the Blood Pressure (BP) in real
time. It consists of two pulse oximeters: one placed on the back and one on the front of the …