Assessment of damage due to earthquake-induced pounding between the main building and the stairway tower

R Jankowski - Key Engineering Materials, 2007 - Trans Tech Publ
The reports after earthquakes indicate that earthquake-induced pounding between
insufficiently separated structures, or their parts, may cause substantial damage or even …

Non-linear FEM analysis of earthquake-induced pounding between the main building and the stairway tower of the Olive View Hospital

R Jankowski - Engineering Structures, 2009 - Elsevier
The reports after major ground motions indicate that earthquake-induced pounding between
buildings may lead to substantial damage or even collapse of colliding structures. The …

Experimental study on pounding between structures during damaging earthquakes

R Jankowski, A Seleemah, S El-Khoriby… - Key engineering …, 2015 - Trans Tech Publ
Mutual pounding between structures during earthquakes may cause serious structural
damage. The aim of this paper is to show the results of a shaking table experimental study …

Determination of peak impact force for buildings exposed to structural pounding during earthquakes

SM Khatami, H Naderpour, RC Barros… - Geosciences, 2019 - mdpi.com
Structural pounding between adjacent, insufficiently separated buildings, or bridge
segments, has been repeatedly observed during seismic excitations. Such earthquake …

Earthquake-induced pounding between the main buildings of the

A Fiore, P Monaco - Earthquakes and Structures, 2010 - koreascience.kr
Historical buildings in seismically active regions are severely damaged by earthquakes,
since they certainly were not designed by the original builders to withstand seismic effects …

Building damage due to structural pounding during earthquakes

B Sołtysik, R Jankowski - Journal of Physics: Conference Series, 2015 - iopscience.iop.org
Earthquake-induced pounding between adjacent buildings has been identified as one of the
reasons for substantial damage or even total collapse of colliding structures. A major reason …

[图书][B] Earthquake-induced structural pounding

R Jankowski, S Mahmoud - 2015 - Springer
It has been observed during earthquakes that adjacent building, or bridge segments, might
come into contact if the separation distance between them is not sufficient so as to …

Mitigation of pounding between adjacent buildings in earthquake situation

V Warnotte - 2007 - orbi.uliege.be
Adjacent buildings subjected to seismic excitations collide against each other when the
separation distance is not large enough to accommodate the displacement response of the …

Earthquake-induced pounding between equal height buildings with substantially different dynamic properties

R Jankowski - Engineering structures, 2008 - Elsevier
Earthquake-induced structural pounding may result in considerable damage or even
collapse of colliding structures during severe ground motions. The aim of the paper is to …

Pounding of an 18-story building during recorded earthquakes

FR Rojas, JC Anderson - Journal of Structural Engineering, 2012 - ascelibrary.org
Abstract During the San Fernando Earthquake (1971), two of the three triaxial recording
instruments placed in an 18-story steel building in Los Angeles recorded the impact with an …