Three-phase grid voltage synchronization using sinusoidal amplitude integrator in synchronous reference frame

X Du, Y Liu, G Wang, P Sun, HM Tai, L Zhou - International Journal of …, 2015 - Elsevier
Synchronization with the grid voltage is critical in the control of grid-connected power
converters. Under unbalanced grid condition, the conventional synchronous reference frame …

Grid-voltage Synchronization Algorithms Based on Phase-locked Loop and Frequency-locked Loop for Power Converters

K Fuad - 2014 - aaltodoc.aalto.fi
The purpose of this thesis is to study and find the appropriate grid-voltage synchronization
method for grid-connected converters under different kinds of faults like phase unbalancing …

Phase-locked loop based on an observer for grid synchronization

Y Park, SK Sul, WC Kim, HY Lee - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
A grid synchronization technique is essential for grid-connected power converters. Phase-
locked loop (PLL) has been widely exploited as an implementation technique, but additional …

A novel phase locked loop for grid-connected converters under non-ideal grid conditions

LY Yang, CL Wang, JH Liu, CX Jia - Journal of Power Electronics, 2015 - koreascience.kr
Grid synchronization is one of the key techniques for the grid-connected power converters
used in distributed power generation systems. In order to achieve fast and accurate grid …

[HTML][HTML] Enhanced PLL-less grid synchronization algorithm amidst unbalanced and distorted three-phase grid conditions

M Kumar, RK Jarial, AK Verma, R Nath, M Torres… - International Journal of …, 2023 - Elsevier
Fast and precise tracking of grid voltage attributes is essential for the smooth and reliable
control and operation of grid-side converters. The synchronous reference-frame phase …

Grid harmonics and voltage unbalance effect elimination for three-phase PLL grid synchronization algorithm

A Safayet, I Husain, A Elrayyah… - 2013 IEEE Energy …, 2013 - ieeexplore.ieee.org
The conventional synchronous reference frame phase locked loop (SRF-PLL) works
perfectly for synchronization of utility interactive systems with grid that has no imperfections …

Grid synchronization PLL robust to frequency variation, unbalanced and distorted voltage

S Lee, JH Lee, H Cha - 2011 IEEE Energy Conversion …, 2011 - ieeexplore.ieee.org
In this paper, Grid synchronization Phase Locked Loop (PLL) robust to frequency Variation,
unbalanced and distorted voltage is proposed. The proposed PLL is based on a decoupling …

Improving the Decoupled Double SRF PLL for grid connected power converters

A Nouralinejad, A Bagheri, M Mardaneh… - The 5th Annual …, 2014 - ieeexplore.ieee.org
One of the critical issues in control of grid connected power converters is synchronization
with the utility voltage. Decoupled Double Synchronous Reference Frame Phase-Locked …

A grid synchronization PLL method based on mixed second-and third-order generalized integrator for DC offset elimination and frequency adaptability

C Zhang, X Zhao, X Wang, X Chai… - IEEE Journal of …, 2018 - ieeexplore.ieee.org
The second-order generalized integrator (SOGI) has been widely used to implement grid
synchronization for grid-connected inverters, and from grid voltages, it is able to extract the …

A combined phase locked loop technique for grid synchronization of power converters under highly distorted grid conditions

N Daou, F Khatounian - 2016 IEEE International …, 2016 - ieeexplore.ieee.org
In power distribution networks, the fundamental positive-sequence component detection of
the utility voltage is required to synchronize the control reference signals of power …