Measurement of the chirp characteristics of linearly chirped pulses by a frequency domain interference method

W Fan, B Zhu, Y Wu, F Qian, M Shui, S Du, B Zhang… - Optics …, 2013 - opg.optica.org
A linear optical technique for chirp characteristics measurement based on frequency domain
interference is developed. This technique can be applied to measure the temporal structure …

Direct and second harmonics interferometric determination of chirped pulse parameters

JT Manassah - Applied optics, 1987 - opg.optica.org
In a recent Letter [1] we proved that both the width and chirp rate of an ultrafast chirped pulse
can be experimentally determined through a single-shot measurement technique. The …

Interferometric characterization of chirped ultrafast pulses

JT Manassah - Applied optics, 1986 - opg.optica.org
In this Letter we investigate a direct interferometric technique as a tool to investigate the
chirp rate of an ultrafast pulse. The intensity distribution associated with the Young …

Propagation dependence of chirp in Gaussian pulses and beams due to angular dispersion

D Li, S Zeng, Q Luo, P Bowlan, V Chauhan, R Trebino - Optics letters, 2009 - opg.optica.org
The chirp acquired by a Gaussian ultrashort pulse due to angular dispersion, unlike that of
plane waves, increases nonlinearly with propagation distance and eventually asymptotes to …

Chirped light and its characterization using the cross-correlation technique

KW Delong, J Yumoto - JOSA B, 1992 - opg.optica.org
We analyze the cross-correlation (sum-frequency generation) method of chirp measurement
of short light pulses. We find that there are two complementary methods to measure the …

A novel real-time chirp measurement method for ultrashort optical pulses

K Mogi, K Naganuma, H Yamada - Japanese journal of applied …, 1988 - iopscience.iop.org
Rapid measurements of ultrashort optical pulse chirping were realized with a newly
developed real-time chirp monitor. The application of a moving coil translator and electrical …

Phase-sensitive single-pulse autocorrelator for ultrashort laser pulses

G Szabó, Z Bor, A Müller - Optics letters, 1988 - opg.optica.org
Phase-sensitive single-pulse autocorrelator for ultrashort laser pulses clickable element to
expand a topic LOGIN OR CREATE ACCOUNT PRISM SUBMISSION This website uses …

Complete characterization of picosecond optical pulses by the offset frequency intensity modulation

K Oguchi, S Nitanai, Y Ozeki - Optics Letters, 2022 - opg.optica.org
We present a method for characterizing the intensity waveform, spectrum, frequency chirp,
and spectral phase of picosecond pulses at a moderate repetition rate of∼ 100? MHz. The …

Sensitive ultrashort pulse chirp measurement

DA Bender, MP Hasselbeck, M Sheik-Bahae - Optics letters, 2006 - opg.optica.org
The chirp of an ultrashort laser pulse can be extracted with high accuracy from a modified
spectrum autointerferometric correlation waveform by using a new time domain algorithm …

Direct measurement of chirped optical pulses with picosecond resolution

ASL Gomes, AS Gouveia-Neto, JR Taylor - Electronics Letters, 1986 - infona.pl
Direct measurement of chirped optical pulses with picosecond resolution × Close The
Infona portal uses cookies, ie strings of text saved by a browser on the user's device. The …