Subclinical myocardial injury in small-for-gestational-age neonates

T Chaiworapongsa, J Espinoza… - The Journal of …, 2002 - Taylor & Francis
Objective: Small-for-gestational-age (SGA) infants are at risk for premature death from
cardiovascular disease (myocardial infarction and stroke), hypertension, and diabetes in …

How much and for how long does the neonatal myocardium suffer from mild perinatal asphyxia?

C Cavalli, RM Dorizzi, L Lanzoni… - The Journal of …, 2005 - Taylor & Francis
Cardiac troponins can be useful in monitoring cardiac injury following perinatal distress. We
report here an increase of cardiac troponin I (cTnI) to 2.84 μg/l at 3 weeks (age-related …

Frequency of elevations in markers of cardiomyocyte damage in otherwise healthy newborns

SE Lipshultz, VC Simbre II, S Hart, N Rifai… - The American journal of …, 2008 - Elsevier
Myocardial damage in infancy is a risk factor for eventual cardiac disease. Given that
myocardial stress is greatest during the perinatal period and that the neonatal period is …

Troponin‐T levels in perinatally asphyxiated infants during the first 15 days of life

T GÜNES, MA ÖZTÜRK, SM Köklü, N Narin… - Acta …, 2005 - Wiley Online Library
Aim: To measure serial cardiac troponin‐T, creatine kinase, creatine kinase‐MB, aspartate
aminotransferase, alanine aminotransferase and lactate dehydrogenase levels in …

Is serum troponin T a useful marker of myocardial damage in newborn infants with perinatal asphyxia?

S Costa, E Zecca, G De Rosa, D De Luca… - Acta …, 2007 - Wiley Online Library
Aim: To assess the correlation of echocardiographic signs of myocardial damage to serum
cardiac troponin T (cTnT) concentrations in newborn infants with perinatal asphyxia …

Serum levels of cardiac troponin I in asphyxiated neonates predict mortality.

WJ Zhou, F Yu, J Shi, H Yang, SJ Zou… - Clinical Laboratory, 2016 - europepmc.org
Background Cardiac troponin I (cTnI) is a well-established marker for detecting myocardial
ischemic damage in neonates with hypoxic-ischemic encephalopathy. However, the …

Cardiac troponin I at birth is of fetal-neonatal origin

D Trevisanuto, N Doglioni, S Altinier… - Archives of Disease in …, 2009 - fn.bmj.com
Objective: Neonates produce predominantly skeletal muscle troponin I (TnI) in the
myocardium; however, in asphyxiated neonates, high levels of cardiac troponin I (cTnI) have …

Usefulness of cardiac troponin T and echocardiography in the diagnosis of hypoxic myocardial injury of full-term neonates

M Szymankiewicz, M Matuszczak-Wleklak… - Neonatology, 2005 - karger.com
Background: Perinatal asphyxia constitutes a significant problem influencing neonatal
mortality and morbidity. Objectives: The aim of the present work was to provide evidence of …

Diagnostic value of troponin T in neonates of mild pre-eclamptic mothers

N Narin, N Çetin, H Kılıç, M Başbuğ, F Narin, M Kafalı… - Neonatology, 1999 - karger.com
The measurement of myocardial damage by newer, highly specific markers of myocardial
damage is now possible, including cardiac structural proteins such as troponin T (TnT). In …

Cardiac troponin I in asphyxiated neonates

D Trevisanuto, G Picco, R Golin, N Doglioni, S Altinier… - Neonatology, 2006 - karger.com
Abstract Background: Cardiac troponins T (cTnT) and I (cTnI) are well-established markers
in detecting myocardial ischemic damage in adults. Perinatal asphyxia is associated with …