Fabrication of transition edge sensor X-ray microcalorimeters for Constellation-X

JA Chervenak, FM Finkbeiner, TR Stevenson… - Nuclear Instruments and …, 2004 - Elsevier
NASA's Constellation-X (Con-X) mission is a driver for advancing low-temperature detector
technologies, requiring 1000-pixel two-dimensional arrays with> 95% filling fraction and …

High-density arrays of x-ray microcalorimeters for Constellation-X

CA Kilbourne, SR Bandler, AD Brown… - … II: Ultraviolet to …, 2006 - spiedigitallibrary.org
We have been developing x-ray microcalorimeters for the Constellation-X mission. Devices
based on superconducting transition-edge sensors (TES) have demonstrated the potential …

Large‐Absorber TES X‐ray Microcalorimeters and the Micro‐X Detector Array

ME Eckart, JS Adams, SR Bandler… - AIP Conference …, 2009 - pubs.aip.org
We present experimental results and designs of large‐absorber transition‐edge‐sensor
(TES) X‐ray microcalorimeters. Much of our effort has focused on developing close‐packed …

Toward 100,000-pixel microcalorimeter arrays using multi-absorber transition-edge sensors

SJ Smith, JS Adams, SR Bandler, S Beaumont… - Journal of Low …, 2020 - Springer
We report on the development of multi-absorber transition-edge sensors (TESs), referred to
as 'hydras'. A hydra consists of multiple X-ray absorbers each with a different thermal …

Development of arrays of transition edge sensors for application in X-ray astronomy

MP Bruijn, WMB Tiest, HFC Hoevers, E Krouwer… - Nuclear instruments and …, 2003 - Elsevier
The development of an array of voltage biased superconducting transition edge
microcalorimeters is described. This work is directed to an application in future X-ray …

Performance of TES x-ray microcalorimeters with a novel absorber design

SR Bandler, RP Brekosky, AD Brown… - Journal of Low …, 2008 - Springer
Superconducting transition-edge sensor (TES) microcalorimeters have demonstrated the
Constellation-X requirements for spectral resolution, speed, and pixel size in a close-packed …

Large area transition edge sensor X-ray microcalorimeters for diffuse X-ray background studies

KM Morgan, SE Busch, ME Eckart… - Journal of Low …, 2014 - Springer
We are developing transition edge sensor (TES) mirocalorimeters with large area (0.72 mm^
2 2) absorbers to study the keV diffuse X-ray background. The goal is to develop a 2 cm^ 2 2 …

Transition-Edge Sensor Optimization for Hard X-ray Applications

D Yan, JC Weber, KM Morgan… - IEEE Transactions …, 2021 - ieeexplore.ieee.org
Arrays of superconducting transition-edge sensor (TES) microcalorimeters are attractive for
some X-ray experiments where the combination of higher collection efficiency than crystal …

Demonstration of fine-pitch high-resolution X-ray transition-edge sensor microcalorimeters optimized for energies below 1 keV

K Sakai, JS Adams, SR Bandler, S Beaumont… - Journal of Low …, 2020 - Springer
In this paper, we report on X-ray transition-edge sensor (TES) microcalorimeters optimized
to have the best possible energy resolution for a limited energy range for the incoming X …

Close-packed arrays of transition-edge x-ray microcalorimeters with high spectral resolution at 5.9 keV

N Iyomoto, SR Bandler, RP Brekosky, AD Brown… - Applied Physics …, 2008 - pubs.aip.org
We present measurements of high fill-factor arrays of superconducting transition-edge x-ray
microcalorimeters designed to provide rapid thermalization of the x-ray energy. We …