The effects of ribs and tip wall distance on heat transfer for a varying aspect ratio two-pass ribbed internal cooling channel

SC Jenkins, F Zehnder… - Journal of …, 2013 - asmedigitalcollection.asme.org
Internal cooling channels with differing aspect ratios are typically found in gas turbine blades
due to the varying thickness of the blade from the leading to trailing edge. These serpentine …

The effect of ribs and tip wall distance on heat transfer for a varying aspect ratio two-pass ribbed internal cooling channel

SC Jenkins, F Zehnder… - … Expo: Power for …, 2008 - asmedigitalcollection.asme.org
Internal cooling channels with differing aspect ratios are typically found in gas turbine blades
due to the varying thickness of the blade from the leading to trailing edge. These serpentine …

Numerical investigations of pressure loss and heat transfer in a 180 bend of a ribbed two-pass internal cooling channel with engine-similar cross-sections

M Schüler, SO Neumann… - Proceedings of the …, 2010 - journals.sagepub.com
Numerical investigations of a two-pass internal cooling channel with engine representative
cross-sections related to turbine blade cooling were conducted. The channel consisted of a …

The effect of turning vanes on pressure loss and heat transfer of a ribbed rectangular two-pass internal cooling channel

F Zehnder, M Schu¨ ler… - … Expo: Power for …, 2009 - asmedigitalcollection.asme.org
Gas turbine blades are usually cooled by using ribbed serpentine internal cooling passages
which are fed by extracted compressor air. The individual straight ducts are connected by …

The influence of including a partially smooth section in the 2nd leg of an internally ribbed two pass cooling channel

D Pape, S Jenkins… - … Expo: Power for …, 2006 - asmedigitalcollection.asme.org
Internal cooling schemes for blades in a gas turbine engine often are subject to
compromises between increased pressure losses in return for greater levels of heat transfer …

Validation and analysis of numerical results for a varying aspect ratio two-pass internal cooling channel

IV Shevchuk, SC Jenkins… - … Expo: Power for …, 2008 - asmedigitalcollection.asme.org
Numerical results for an internal ribbed cooling channel including a 180° bend with a 2: 1
inlet and 1: 1 aspect ratio outlet channel were validated against experimental results in …

The effect of turning vanes on pressure loss and heat transfer of a ribbed rectangular two-pass internal cooling channel

M Schüler, F Zehnder, B Weigand… - 2011 - asmedigitalcollection.asme.org
Gas turbine blades are usually cooled by using ribbed serpentine internal cooling passages,
which are fed by extracted compressor air. The individual straight ducts are connected by …

Heat transfer and pressure loss in rectangular one-side-ribbed channels with different aspect ratios

S Kunstmann, J Wolfersdorf… - Journal of …, 2013 - asmedigitalcollection.asme.org
An investigation was conducted to assess the thermal performance of W-shaped, 2W-
shaped and 4W-shaped ribs in a rectangular channel. The aspect ratios (W/H) were 2: 1, 4 …

Local heat transfer distribution in a square channel with 90 continuous, 90 saw tooth profiled and 60 broken ribs

A Gupta, V SriHarsha, SV Prabhu, RP Vedula - Experimental Thermal and …, 2008 - Elsevier
Internal channel cooling is employed in advanced gas turbines blade to allow high inlet
temperatures so as to achieve high thrust/weight ratios and low specific fuel consumption …

Heat transfer and pressure loss in rectangular one-side-ribbed channels with different aspect ratios

S Kunstmann, J von Wolfersdorf… - … Expo: Power for …, 2009 - asmedigitalcollection.asme.org
An investigation was conducted to assess the thermal performance of W-shaped, 2W-
shaped and 4W-shaped ribs in a rectangular channel. The aspect ratios (W/H) were 2: 1, 4 …