Uniform high spectral resolution demonstrated in arrays of TES x-ray microcalorimeters

CA Kilbourne, SR Bandler, AD Brown… - UV, X-Ray, and …, 2007 - spiedigitallibrary.org
Individual x-ray calorimeters based on superconducting transition-edge sensors (TES) have
already demonstrated the spectral resolution, speed, and quantum efficiency needed for …

Performance and uniformity of a kilo-pixel array of Ti/Au transition-edge sensor microcalorimeters

E Taralli, M D'Andrea, L Gottardi… - Review of Scientific …, 2021 - pubs.aip.org
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of
x-ray space observatories. These arrays are required to achieve an energy resolution ΔE< 3 …

The X-ray microcalorimeter instruments on the Astro-E2 and Constellation-X X-ray observatories

RL Kelley - Nuclear Instruments and Methods in Physics Research …, 2004 - Elsevier
X-ray microcalorimeter arrays are well suited to address key problems in high-energy
astrophysics. The Japan/US Astro-E2 mission will deploy a 32-pixel array of …

Performance of TES x-ray microcalorimeters with a novel absorber design

SR Bandler, RP Brekosky, AD Brown… - Journal of Low …, 2008 - Springer
Superconducting transition-edge sensor (TES) microcalorimeters have demonstrated the
Constellation-X requirements for spectral resolution, speed, and pixel size in a close-packed …

Close-packed arrays of transition-edge x-ray microcalorimeters with high spectral resolution at 5.9 keV

N Iyomoto, SR Bandler, RP Brekosky, AD Brown… - Applied Physics …, 2008 - pubs.aip.org
We present measurements of high fill-factor arrays of superconducting transition-edge x-ray
microcalorimeters designed to provide rapid thermalization of the x-ray energy. We …

Optimized transition-edge x-ray microcalorimeter with 2.4 eV energy resolution at 5.9 keV

JN Ullom, JA Beall, WB Doriese, WD Duncan… - Applied Physics …, 2005 - pubs.aip.org
We present measurements from a series of transition-edge x-ray microcalorimeters
designed for optimal energy resolution. We used the geometry of the sensors to control their …

Transition-edge sensors for cryogenic x-ray imaging spectrometers

L Gottardi, S Smith - Handbook of X-ray and Gamma-ray Astrophysics, 2022 - Springer
Large arrays of superconducting transition-edge sensor (TES) microcalorimeters are
becoming the key technology for future space-based X-ray observatories and ground-based …

Fabrication of x-ray microcalorimeter focal planes composed of two distinct pixel types

EJ Wassell, JS Adams, SR Bandler… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
We develop superconducting transition-edge sensor (TES) microcalorimeter focal planes for
versatility in meeting the specifications of X-ray imaging spectrometers, including high count …

Experimental Results and Modeling of Low‐Heat‐Capacity TES Microcalorimeters for Soft‐X‐ray Spectroscopy

ME Eckart, JS Adams, SR Bandler… - AIP Conference …, 2009 - pubs.aip.org
Transition‐edge‐sensor (TES) X‐ray microcalorimeters have mostly been targeted at mid‐
band energies from 0.05–10 keV and high energies to above 100 keV. However, many other …

Multiplexed readout of uniform arrays of TES x-ray microcalorimeters suitable for Constellation-X

CA Kilbourne, WB Doriese, SR Bandler… - … 2008: Ultraviolet to …, 2008 - spiedigitallibrary.org
Following our development of a superconducting transition-edge-sensor (TES)
microcalorimeter design that en-ables reproducible, high performance (routinely better than …