Electron capture gas chromatographic methodology for the quantitation of polychlorinated biphenyls: survey and compromise

ASY Chau, RCJ Sampson - Environmental Letters, 1975 - Taylor & Francis
A uniform approach to quantitation of environmental PCB residues was sought. There exists
a requirement for a reasonable compromise between accurate analysis and the ability to …

Field measurement of polychlorinated biphenyls in soil and sediment using a portable gas chromatograph

TM SPITTLER - 1984 - ACS Publications
With the recent increase in activity at hazardous waste sites where cleanup and remedial
action are underway, there has emerged a need for rapid analytical methods for assessing …

Use of reference pools to compare the qualitative and quantitative determination of polychlorinated biphenyls by packed and capillary gas chromatography with …

L Susan - Analyst, 1990 - pubs.rsc.org
Serum for reference pools of in vivo polychlorinated biphenyls (PCBs) was obtained from
four goats that had received one dose (100 mg kg–1) of a selected technical Aroclor …

Polychlorinated biphenyls in the environment

V Lang - Journal of Chromatography A, 1992 - Elsevier
This review surveys the problems arising from the release of PCBs into the environment from
the point of view of the analytical chemist. These problems are very complex and …

Development of methane positive chemical ionization gas chromatography mass spectrometry procedures to determine polychlorinated biphenyl

RD Voyksner, JT Bursey, TW Pack… - Analytical …, 1986 - ACS Publications
Positive Ion chemical ionization GC/MS was evaluated for the quantitation of
polychloroblphenyls (PCBs) using 10 or less selected PCB standards. Positive Ion chemical …

Quantitation of polychlorinated biphenyl residues by electron capture gas-liquid chromatography: collaborative study

LD Sawyer - Journal of the Association of Official Analytical …, 1978 - academic.oup.com
Ten collaborators quantitated 2 synthetically prepared polychlorinated biphenyl (PCB)
mixtures, 2 PCB-fortified milk samples, and an incurred PCB residue in milk and chicken fat …

Identification and determination of polychlorinated biphenyls by high-resolution gas chromatography

FI Onuska, RJ Kominar, KA Terry - Journal of Chromatography A, 1983 - Elsevier
We have developed an integrated analytical procedure for polychlorinated biphenyl (PCB)
multiresidues in sediment samples that enables quantitation of PCB residues at levels as …

Characterization of polychlorinated biphenyl isomers in Sovol and Trichlorodiphenyl formulations by high-resolution gas chromatography with electron capture …

V Ivanov, E Sandell - Environmental science & technology, 1992 - ACS Publications
Since the discovery of polychlorinated biphenyls (PCBs) in environmental samples in 1966
(1), it has been generally accepted that they are ubiquitous contaminants of every …

Mass spectrometric determination of polychlorinated biphenyls as isomer groups

JE Gebhart, TL Hayes, AL Alford-Stevens… - Analytical …, 1985 - ACS Publications
A procedure to measure concentrations of polychlorinated biphenyls (PCBs) by using nine
selected PCB congeners as concentration calibration standards was developed and ap …

Quantitation of polychlorinated biphenyl residues by electron capture gas-liquid chromatography: reference material characterization and preliminary study

LD Sawyer - Journal of the Association of Official Analytical …, 1978 - academic.oup.com
Weight per cent compositions of individual peaks of Aroclors 1016, 1242, 1248, 1254, and
1260 were determined under standard gas-liquid chromatographic (GLC) conditions. The …