Investigation about influence on breakdown voltage by arc condition befor quenching

R Oshiro, E Kaneko - 2015 3rd International Conference on …, 2015 - ieeexplore.ieee.org
When the contacts of a circuit breaker are opened just before the current zero, the gap
between the contacts after the current interruption will still be very short. Therefore, it cannot …

Dielectric Recovery Characteristics after High‐Frequency Current Interruption in Vacuum Circuit Breaker

S Tamaki, K Ganaha, R Oshiro… - Electrical Engineering in …, 2016 - Wiley Online Library
When the contacts of circuit breaker are opened just before current zero, the gap between
contacts will still be very short. Therefore, it cannot withstand recovery voltage between the …

Re-ignition and post arc current phenomena in low voltage circuit breaker

W Hauer, X Zhou - … 2014; The 27th International Conference on …, 2014 - ieeexplore.ieee.org
Re-ignition during short circuit interruption process is one of the most important phenomena
circuit breaker design engineers have to deal with. It has direct impact on short circuit …

Post-arc current of vacuum DC interruption

T Qin, D Liang, E Dong, J Zou - 2017 4th International …, 2017 - ieeexplore.ieee.org
Post-arc current significantly influences the interrupting process of breakers, which can
reflect the appearance of the arc before current zero and the residual metal vapors in …

Study on dielectric recovery characteristics after high frequency current interruption in vacuum circuit breaker with short gap

S Tamaki, K Ganaha, S Miyamoto… - … on Discharges and …, 2014 - ieeexplore.ieee.org
When inductive load is interrupted by VCB, extinction and re-ignition may be observed
repeatedly by balance with recovery voltage. This is due to high frequency current …

[HTML][HTML] SF6 Experimental Study on the Variation Characteristics of Closing Prebreakdown Duration during Contact Deterioration of Circuit Breakers

F Ma, C Xu, B Niu, Y Wang, Z Xiang, Q Wu, J Bao - Energies, 2024 - mdpi.com
The contact morphology change caused by high-current ablation will seriously affect the
electric field distribution in the interrupter chamber, which in turn affects the closing …

[HTML][HTML] Study on Short-circuit current interruption characteristics of Double-break fast vacuum circuit breaker within the minimum arcing time

C Guan, J Ding, X Yao, J Zheng, S Mu, Z Liu… - International Journal of …, 2023 - Elsevier
It is significant for circuit breakers to expel a short-circuit fault in a short time for the new
power grid with high proportional photovoltaic or wind power plants to achieve high transient …

Study on the influencing factors of reignition characteristics for 40.5 kV vacuum circuit breakers

J Yan, Z Ma - 2006 International Conference on Power System …, 2006 - ieeexplore.ieee.org
When 40.5 kV vacuum circuit breakers are used to break currents in distribution system,
reignition phenomena occur frequently resulting in high overvoltage and even interruption …

Experiment research on current chopping on zero period of DC vacuum circuit breaker breaking

X Li, J Zou, L Geng, Z Bi - 2017 4th International Conference on …, 2017 - ieeexplore.ieee.org
Dielectric recovery after arc extinguishes in vacuum circuit breaker is very fast, the arc
current may be cut off before natural current zero. In order to study the current zero period …

Improvement of Dielectric Recovery Performance for Self Blast Circuit Breaker

MH Kim, KH Kim, HJ Jeong, A Smajkic… - … on Electric Power …, 2019 - ieeexplore.ieee.org
The self-blast type circuit breaker has been developed to reduce mechanical operation
energy by building up the pressure of arc extinguishing gas flow from the heat of the arc …