[PDF][PDF] Ischemia modified albumin in patients of cardiac and non-cardiac chest pain

K Aggarwal, S Seth, K Dahiya, HK Aggarwal… - Biomed …, 2011 - researchgate.net
Existing biochemical markers are not suitable for assessing early myocardial ischemia
particularly in first 2-6 hours of ischemia ie before setting in of irreparable myocardial …

Serum levels of ischemia-modified albumin (IMA) in healthy adults and patients with acute coronary syndrome

S Ozdem, Y Cete, L Donmez, I Basarici, A Baktir… - Tr J Emerg …, 2005 - trjemergmed.com
Introduction: Serum levels of ischemia-modified albumin (IMA) has recently been introduced
as an early marker of myocardial ischemia in management of patients with acute coronary …

Estimation of ischemia modified albumin (IMA) levels in patients with acute coronary syndrome

P Gurumurthy, SK Borra, RKR Yeruva, D Victor… - Indian Journal of Clinical …, 2014 - Springer
Myocardial ischemia produces free radicals that catalyze a series of oxidative reactions that
damage healthy tissues. The N-terminal sequence of albumin is one of the proteins modified …

Ischemia modified albumin: A novel marker for acute coronary syndrome

R Chawla, N Goyal, R Calton, S Goyal - Indian Journal of Clinical …, 2006 - Springer
Early identification of patients with acute myocardial infarction is of prime importance due to
the associated very high mortality. Only 22% of the patients presenting at emergency …

Ischemia-modified albumin: is it a reliable diagnostic and prognostic marker for myocardial ischemia in real clinical practice?

JS Kim, HJ Hwang, YG Ko, JS Kim, D Choi, JW Ha… - Cardiology, 2010 - karger.com
Objectives: We investigated whether ischemia-modified albumin (IMA), a novel biomarker of
acute myocardial ischemia, is reliable for diagnosing ischemic chest pain and predicting …

Use of ischemia-modified albumin in diagnosis of coronary artery disease

N Kalay, Y Cetinkaya, E Basar… - Coronary artery …, 2007 - journals.lww.com
Objective The diagnosis of coronary artery disease (CAD) is an important clinical problem.
Ischemia-modified albumin (IMA) has been demonstrated to be a helpful marker in detecting …

Ischaemia modified albumin in patients with acute coronary syndrome and negative cardiac troponin I

G Sygitowicz, J Janas, S Białek… - … Journal of Clinical …, 2013 - Taylor & Francis
Abstract Background. Approximately 40–60% of patients with acute coronary syndrome
(ACS) have normal cardiac troponin I (cTnI) concentrations on admission. Ischaemia …

Evaluation of ischemia-modified albumin in myocardial infarction and prostatic diseases

AK Mastella, RN Moresco, DB da Silva… - Biomedicine & …, 2009 - Elsevier
BACKGROUND: Ischemia-modified albumin (IMA) has been shown to be a rapidly rising
and sensitive biochemical marker for the diagnosis of myocardial ischemia. In this study, we …

Ischemia modified albumin: a potent marker in acute myocardial infarction in normolipidaemic

K Arun, S Rahmiah, G Susil - 2008 - pesquisa.bvsalud.org
Currently, there are no well-defined biochemical markers for identification of myocardial
ischemia in normolipidaemic AMI individuals. Biochemical markers such as CK-MB, cTnl …

Ischemia modified albumin: a novel biomarker for the detection of cardiac ischemia

DC Gaze - Drug metabolism and pharmacokinetics, 2009 - Elsevier
The diagnosis of cardiac ischemia remains a challenge in contemporary emergency
medicine. A blood-borne biomarker is an attractive alternative to cardiac imaging or stress …