Arraying compact pixels of transition-edge microcalorimeters for imaging x-ray spectroscopy

CK Stahle, MA Lindeman… - AIP Conference …, 2002 - pubs.aip.org
We are developing superconducting transition-edge sensor (TES) microcalorimeters for
astronomical x-ray spectroscopy. We have obtained very high energy resolution (2.4 eV at …

Performance of an X-ray Microcalorimeter with a 240 μm Absorber and a 50 μm TES Bilayer

AR Miniussi, JS Adams, SR Bandler… - Journal of Low …, 2018 - Springer
Superconducting transition-edge sensor (TES) microcalorimeters are being developed for a
variety of potential astrophysics missions, including Athena. The X-ray integral field unit …

Progress in the development of Mo/Au transition-edge sensors for x-ray spectroscopy

CK Stahle, RP Brekosky… - X-Ray and Gamma …, 2000 - spiedigitallibrary.org
X-ray microcalorimeters using transition-edge sensors (TES) show great promise for use in
astronomical x-ray spectroscopy. We have obtained very high energy resolution (2.8 eV at …

Fabrication of x-ray microcalorimeter focal planes composed of two distinct pixel types

EJ Wassell, JS Adams, SR Bandler… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
We develop superconducting transition-edge sensor (TES) microcalorimeter focal planes for
versatility in meeting the specifications of X-ray imaging spectrometers, including high count …

Fabrication of Mo/Au transition-edge sensors for X-ray spectrometry

N Tralshawala, RP Brekosky, MJ Li… - IEEE transactions on …, 2001 - ieeexplore.ieee.org
We present fabrication details of our Mo/Au X-ray microcalorimeters, which are being
developed as one of the candidate high resolution spectrometers for the Constellation-X …

A review of x-ray microcalorimeters based on superconducting transition edge sensors for astrophysics and particle physics

L Gottardi, K Nagayashi - Applied Sciences, 2021 - mdpi.com
The state-of-the-art technology of X-ray microcalorimeters based on superconducting
transition-edge sensors (TESs), for applications in astrophysics and particle physics, is …

Fine pitch transition-edge sensor X-ray microcalorimeters with sub-eV energy resolution at 1.5 keV

SJ Lee, JS Adams, SR Bandler, JA Chervenak… - Applied Physics …, 2015 - pubs.aip.org
We are developing arrays of X-ray microcalorimeters on a 50-µm pitch that utilize transition-
edge sensors as the sensor to measure the temperature rise when X-rays are absorbed. An …

Development of a Ti/Au TES microcalorimeter array as a backup sensor for the Athena/X-IFU instrument

K Nagayoshi, ML Ridder, MP Bruijn, L Gottardi… - Journal of Low …, 2020 - Springer
We are developing a transition edge sensor (TES) microcalorimeter array based on a Ti/Au
superconducting bilayer, as a backup option for the X-IFU instrument on the Athena X-ray …

Performance of TES x-ray microcalorimeters with a novel absorber design

SR Bandler, RP Brekosky, AD Brown… - Journal of Low …, 2008 - Springer
Superconducting transition-edge sensor (TES) microcalorimeters have demonstrated the
Constellation-X requirements for spectral resolution, speed, and pixel size in a close-packed …

Development of arrays of transition edge sensors for application in X-ray astronomy

MP Bruijn, WMB Tiest, HFC Hoevers, E Krouwer… - Nuclear instruments and …, 2003 - Elsevier
The development of an array of voltage biased superconducting transition edge
microcalorimeters is described. This work is directed to an application in future X-ray …