Real-time implementation of robust controller for PV emulator supplied shunt active power filter

H Afghoul, F Krim, A Beddar… - 2018 6th International …, 2018 - ieeexplore.ieee.org
The aim of this paper is an implementation of shunt active power filter (SAPF) supplied by
PV generator dedicated to power quality improvement, power factor correction and smooth …

Photovoltaic interfaced shunt active power filter under online-varying parameters based on fuzzy logic controller and adaptive hysteresis band current controller

A Azzam-Jai, M Ouassaid - 2019 Third International …, 2019 - ieeexplore.ieee.org
This paper explores performances of the photovoltaic plant associated with shunt active
power filter (PV-SAPF). The model guarantees uninterrupted power quality, with the benefit …

Interactive PV-Shunt Active Power Filter with Fuzzy-MPPT Controller for Power Quality Improvement

A Kouzou, A Teta, MM Rezaoui… - 2022 5th International …, 2022 - ieeexplore.ieee.org
This paper presents a three-phase shunt active power filter connected to a Photovoltaic (PV)
source by the means of DC-DC boost converter for total harmonic distortion (THD) reduction …

FPA tuned extended Kalman filter for power quality enhancement in PV integrated shunt active power filter

SK Prince, KP Panda, M Patowary… - … on computing, power …, 2019 - ieeexplore.ieee.org
Harmonics in the system degrade the quality of power. Due to obvious presence power
converters and nonlinear loads in the system, impact of harmonic increases. This …

Experimental investigation of shunt active power filter for power quality enhancement

C Biswal, R Panigrahi, R Patjoshi - 2023 IEEE Renewable …, 2023 - ieeexplore.ieee.org
This paper describes a digital approach to plan a control algorithm intended for single-
phase shunt active power filter (SAPF) in regard to lessen current harmonics as well as …

Quality improvement of shunt active power filter with direct instantaneous power estimator based on Virtual Flux

S Saidi, R Abbassi, S Chebbi - International Journal of Control …, 2016 - Springer
This paper presents a new control strategy which is based on a switching table applied for
Virtual Flux Direct Power Control (VF-DPC) of voltage source inverter based shunt active …

Improved control of shunt active power filter connected to a photovoltaic system using technique of direct power control

A Krama, L Zellouma, B Rabhi - 2016 8th International …, 2016 - ieeexplore.ieee.org
In the area of sustainable development, solar energy has shown significant potential as a
renewable energy source and it considered the important one in electricity generation. This …

[PDF][PDF] Anti-windup proportional integral strategy for shunt active power filter interfaced by photovoltaic system using technique of direct power control

A Krama, L Zellouma, B Rabhi - Revue Roumaine des Sciences …, 2017 - academia.edu
This paper focuses on power quality improvement in the distribution network using three
phase shunt active power filter, where this later is connected to photovoltaic system. In the …

Fuzzy logic controller based Shunt Active Power filter for current harmonic compensation

EM Thajeel, MM Mahdi, EI Abbas - … International Conference on …, 2020 - ieeexplore.ieee.org
This paper presents the performance investigation of three phase shunt active power filter
(SAPF) using proportional integral (PI) and Fuzzy Logic controller (FLC). The control …

Power quality improvement of solar PV system with shunt active power filter using FS-MPC method

M Manohara, VCV Reddy… - 2023 IEEE Renewable …, 2023 - ieeexplore.ieee.org
In recent years, photovoltaic (PV) power generation has become one of the most significant
renewable energy technologies. In the field of renewable energy sources, the usage of …