The influence of reinforcement steel surface condition on initiation of chloride induced corrosion

D Boubitsas, L Tang - Materials and Structures, 2015 - Springer
This paper describes a part of the work in the development of a “standard” test method for
determining chloride threshold values required to initiate corrosion on reinforcement in …

Critical chloride threshold values as a function of cement type and steel surface condition

C Chalhoub, R François, M Carcasses - Cement and Concrete Research, 2020 - Elsevier
This paper presents the application of a new test protocol developed for determining
chloride threshold values initiating corrosion in reinforced concrete. The experimental set-up …

A method for measuring the chloride threshold level required to initiate reinforcement corrosion in concrete

PV Nygaard, MR Geiker - Materials and Structures, 2005 - Springer
Abstract Information on the chloride threshold level that is necessary to initiate corrosion of
steel reinforcement in concrete is required for service life calculations and performance …

Determination of chloride threshold initiating corrosion: A new set-up taking the localized aspect of corrosion into account

C Chalhoub, R François, M Carcasses - Cement and Concrete Research, 2019 - Elsevier
In spite of much research invested in the study of concrete reinforcement corrosion induced
by chlorides, there is still no agreement on an accurate method for determining the chloride …

Potential pitfalls in assessing chloride-induced corrosion of steel in concrete

A Poursaee, CM Hansson - Cement and Concrete Research, 2009 - Elsevier
Electrochemical assessment of the condition of embedded reinforcing bar (rebar) in
concrete is being carried out increasingly routinely, both in the laboratory and in the field …

[PDF][PDF] Investigations on cathodic control of chloride-induced reinforcement corrosion

M Raupach, J Gulikers - European Federation of Corrosion …, 2000 - s1.iran-mavad.com
There are still contradictions regarding the mechanisms of reinforcement corrosion with
respect to the controlling rate-determining factors of the corrosion process. It is often stated …

Mathematical relation of steel thickness loss with time related to reinforced concrete contaminated by chlorides

V Bouteiller, E Marie-Victoire, C Cremona - Construction and Building …, 2016 - Elsevier
Corrosion of chloride contaminated reinforced concretes exposed to outdoor conditions and
to six controlled environmental conditions was followed within a five year study. Corrosion …

Chloride induced reinforcement corrosion: Electrochemical monitoring of initiation stage and chloride threshold values

UM Angst, B Elsener, CK Larsen, Ø Vennesland - Corrosion Science, 2011 - Elsevier
Reinforcement steel embedded in six different concrete mixes was exposed to chloride by
wetting/drying cycles. Various parameters were continuously monitored during more than …

Chloride-induced corrosion on reinforcing steel: from the fundamentals to the monitoring techniques

MF Montemor, AMP Simoes, MGS Ferreira - Cement and concrete …, 2003 - Elsevier
One of the most important causes for reinforcing steel corrosion is the presence of chloride
ions. They cause localised breakdown of the passive film that initially forms on steel as a …

[PDF][PDF] Influence of casting direction on chloride-induced rebar corrosion

U Angst, CK Larsen, O Vennesland… - Concrete under Severe …, 2010 - ndl.ethernet.edu.et
The steel/concrete interface is one of the major influencing factors for chloride-induced
reinforcement corrosion. Its properties are highly dependent on conditions during casting …