Investigation of impact of DC component on breakdown characteristics for different electric fields under composite AC & DC voltage

MM Ispirli, Ö Kalenderli, F Seifert, M Rock… - High Voltage, 2022 - Wiley Online Library
The valve side of the converter in the high‐voltage direct current is subjected to mixed
voltages such as composite AC & DC voltage. In this study, the effects of the homogeneity of …

Comparative study on various dielectric barriers and their effect on breakdown voltage

E Foruzan, AAS Akmal, K Niayesh, J Lin… - High …, 2018 - Wiley Online Library
Non‐pressurised air is extensively used as basic insulation medium in high‐voltage
equipment. Unfortunately, an inherent property of air‐insulated design is that the system …

The Effect of DC Voltage Pre-Stress on the Breakdown Voltage of Air under Composite DC and LI Voltage and Test Circuit: Design and Application

MM Ispirli, Ö Kalenderli, F Seifert, M Rock, B Oral - Energies, 2022 - mdpi.com
The use of HVDC systems is increasing in number due to technological innovations,
increasing power capacity and increasing customer demand. The characteristics of …

Breakdown characteristics of rod-plate electrode under composite AC and DC voltage

C Li, T Lu, Y Zhang, B Bai, X Li - 2020 IEEE International …, 2020 - ieeexplore.ieee.org
With enhancement of voltage level, the parts such as fittings, shields and insulator of
converter valve which is an important equipment in the high voltage direct current (HVDC) …

The investigation of dielectric barrier impact on the breakdown voltage in high voltage systems by modeling and simulation

E Foruzan, H Vakilzadian - 2015 IEEE Power & Energy Society …, 2015 - ieeexplore.ieee.org
Nonpressurized air is used extensively as a basic insulation medium in medium/high
voltage equipment. An inherent problem of air-insulated designs is that the systems tend to …

Experimental investigation of the corona discharge in electrical transmission due to AC/DC electric fields

P Fuangpian, T Zafar, S Ruankorn… - MATEC Web of …, 2016 - matec-conferences.org
Nowadays, using of High Voltage Direct Current (HVDC) transmission to maximize the
transmission efficiency, bulk power transmission, connection of renewable power source …

[PDF][PDF] Analysis of DC Breakdown Characteristics in Different Types Electrodes

HCT Fan, LJ Ann, KW Loon, PY Khai… - J. Eng. Sci. Technol …, 2019 - academia.edu
Abstract The use of High Voltage (HV) apparatus in the HV transmission line has been in
high demand since the realization of two main electrical power transmission approaches …

Influence of insulation barrier on AC flashover voltage with and without grounded back electrode in air

J Liu, GG Karady - IEEE Transactions on Dielectrics and …, 2015 - ieeexplore.ieee.org
The grounded back electrode can reduce the breakdown voltage. Inserting an insulation
barrier is an effective way to increase breakdown voltage. The objective of this paper is to …

Experimental and numerical study on corona onset threshold under combined AC-DC voltages in Wire-Plane electrodes

Z Ma, J Xia, X He, Y Zhou, Z He, Q Li, X Bian - International Journal of …, 2022 - Elsevier
With the large-scale application of hybrid HVDC/HVAC transmission technology, the
phenomenon of corona discharge is also intensified. This paper attempts to provide a …

Investigation about influence on breakdown voltage by arc condition befor quenching

R Oshiro, E Kaneko - 2015 3rd International Conference on …, 2015 - ieeexplore.ieee.org
When the contacts of a circuit breaker are opened just before the current zero, the gap