Laser fluorometry of fluorescein and riboflavin

N Ishibashi, T Ogawa, T Imasaka… - Analytical chemistry, 1979 - ACS Publications
The detection limits of fluorescein and riboflavin are determined to be 0.02 and 0.6 parts-per-
trillion, respectively, with the use of a very sensitive fluorometric system (a nitrogen …

Detection limit of fluorescein as determined by fluorometry with an esculin laser source

T Imasaka, H Kadone, T Ogawa… - Analytical Chemistry, 1977 - ACS Publications
Sir: Fluorometric analysis provides a useful method for the determination of the ppb level of
the fluorescing molecule. In principle, the sensitivity can be raised by using a more intense …

High-sensitivity laser fluorometer

B Kirsch, E Voigtman, JD Winefordner - Analytical Chemistry, 1985 - ACS Publications
Sir: It is well-known that laser-induced fluorescence is a very sensitive technique for
ultratrace analysis. Various combinations of laser sources and detection systems have been …

New type of spectrofluorometer with a tunable laser source and unique optical system

DC Harrington, HV Malmstadt - Analytical Chemistry, 1975 - ACS Publications
A new type of spectrofluorometer has been developed which utilizes a single modified
monochromator both as a tunable dye laser excitation source and as a scanning mo …

[引用][C] Sub-part-per-trillion detection of riboflavin by laser-induced fluorescence

JH Richardson, BW Wallin, DC Johnson… - Analytica Chimica …, 1976 - Elsevier
Conventional fluorescence finds many applications in analytical chemistry because of its
sensitivity and selectivity f I] _ The recent use of lasers instead of conventional light sources …

Some general aspects of fluorimetric determinations

H Braunsberg, SB Osborn - Analytica Chimica Acta, 1952 - Elsevier
We wish to summarise some of the factors which must be considered in order to choose the
best possible conditions for fluorimetric determinations: 1. The absorption spectrum of the …

Correction of right-angle fluorescence measurements for the absorption of excitation radiation

JF Holland, RE Teets, PM Kelly, A Timnick - Analytical chemistry, 1977 - ACS Publications
The effect of excitation beam absorption on measured values of fluorescence has been
studied with a computer-centered spectrofluorlmeter capable of measuring fluorescence and …

Quantitation of fluorophores in solution by pulsed laser excitation and time-filtered detection

GR Haugen, FE Lytle - Analytical Chemistry, 1981 - ACS Publications
A fluorlmeter employing single photon counting and mode-locked laser excitation was
constructed to test the concept of time-filtered detection. Expressions for a figure of merit and …

Spectrofluorometer Calibration in the Ultraviolet Region.

CA Parker - Analytical Chemistry, 1962 - ACS Publications
Most spectrofluorometers re-cord “apparent” excitation and emission spectra which are a
function of the particular instrument used. Such apparent spectra are often grossly distorted …

Visible semiconductor laser fluorometry

T Imasaka, A Tsukamoto, N Ishibashi - Analytical Chemistry, 1989 - ACS Publications
Table I. Characteristics of Organic Dyes in theDeep-Red Region molar absorption
absorptivity, fluorescence saturated compound max, nm(M cm)" 1 max, nm concn, M …